option
Cuestiones
ayuda
daypo
buscar.php

SRM

COMENTARIOS ESTADÍSTICAS RÉCORDS
REALIZAR TEST
Título del Test:
SRM

Descripción:
Abreviaturas y más

Fecha de Creación: 2025/04/05

Categoría: Ciencia

Número Preguntas: 31

Valoración:(0)
COMPARTE EL TEST
Nuevo ComentarioNuevo Comentario
Comentarios
NO HAY REGISTROS
Temario:

WHICH ATA SPECIFICATION FOLLOW THE MANUFACTURER IN ORDER TO DO THE SRM?. ATA Ispec 2200. ATA 100. ATA 2200.

WHERE WE FIND THE REGISTER, MSN AND WV OF AN AIRCRAFT?. AIRCRAFT CROSS REFERENCE TABLE. AIRCRAFT CROSS REFERENCE TABLES. AIRCRAFHT CROSS REFERENCE TABLE.

WHAT IS THE FIRST DOCUMENT TO BE USED TO REPAIR, ASSESS THE DAMAGE AND IDENTIFY THE AFFECTED AIRCRAFT STRUCTURE?. SRM. SCM. SRA.

WHAT IS THE VERACITY OF THE FOLLOWING "THE SRM USED TO EVALUATE DAMAGE TO AN A319 CAN ALSO BE USED TO ASSESS DAMAGE TO AN A320 AIRCRAFT" TRUE OR FALSE?. True. False.

WHICH ENGINE USE THE A319, A320 AND THE A321. INTERNATIONAL AERO ENGINES AND CFM INTERNATIONAL. INTERNATIONAS AERO ENGINES AND CFM INTERNATIONAL. INTERNATIONAL AERO ENGINES AND CRM INTERNATIONAL.

THE FASTENERS OF THE SAME DIAMETER THAT CAN BE USED INSTEAD OF THE ORIGINAL ARE CALLED. ALTERNATIVE FASTENER. ALTERNATIVED FASTENER. ALTERNATIVE FASTENES.

WHEN A FASTENER HOLE IS DAMAGED AND OUTSIDE THE TOLERANCES FOR THE ORIGINAL FASTENER NOMINAL DIAMETER AN OVERSIZE FASTENER MUST BE INSTALLED. AN OVERSIZE FASTENER MUST BE INSTALLEHD. AN OVERSIZE FASTENER MUST BE INSTALLED. AN OVERSIZED FASTENER MUST BE INSTALLED.

WHAT IS FRAME PITCH?. THE DISTANCE BETWEEN TWO ADJACENT FRAMES. THE DISTANCED BETWEEN TWO ADJACENT FRAMES. THER DISTANCE BETWEEN TWO ADJACENT FRAMES.

D53231715202 IS A PART LOCATED AT LH OR RH SIDE OF THE A/C?. LH. RH. Other.

HOW IS SHOW THE CONFIGURATION CODES IN SRM?. C1, C4, C2. C1, C3, C2. C1, C2, C3.

IN THE IDENTIFICATION TABLE THE WORD "REPLACE" IN THE COLUMN ACTION OR REPAIR, MEANS?. IS A RECOMENDATION. IS A MANDATORY. Is A OPTION.

INFORMATION IN THE IDENTIFICATION IS SHOWN AS?. ILLUSTRATION AND ID TABLES. ILLUSTRATION AND ID TABLETS. ILLUSTRATION AND ID TABLES.

Due to SRM is a Non-customized manual, which effectivity numbers are necessary?. MSN ( manufacturer serial number). MSN. MSN (Genéric and Envelope).

In the following part number D53370354202, which drawing number is?. D53370354. D53370454. D52370354.

Talking abaut function codes i, e,. 53-21-11-283-001, which informátion the 283 codes shows?. Allowable Damage. Allowabled Damage. Allowable Damaged.

Abaut function codes i, e, 53-11-12-300-003, which informátion does the 300 code show?. Reparación. Inspección. Ambos.

What type of Drawing is show by the following P/N D53231715202?. Detalled drawing. Detalleds drawing. Dethalled drawing.

Según el orden de ATAS.... 51. Estructura general 52. Doors 53. Fuselage. 51. Estructura 52. Paylon/nacelles 53. Fuselage. 51. Estructura 52.Doors 53. Wings.

Según el orden de ATAS.... 54.paylon /nacelles 55.stabilizer 56. Windows. 54.paylon /nacelles 55.stabilizer 56. Wings. 54.paylon /nacelles 55.wings 56. Windows.

Según el código de identificación qué significan los primeros 9 números. Número de Drawing. Número de ATA.

Que número nos indica qué es para detallar partes?. 200 hacia arriba. 100 hacia arriba. 300 hacia arriba.

Caracteres 10, 11, 12.... Par number. Locación. Other.

Sistema de locación. 0 o número par LH, número impar RH. 0 o número par RH número impar LH.

Que número de código habla sobre números permicibles?. 285. 283. 284.

Según Cat de daños que daños se consideran Cat A. Considerado como permanente y no requiere inspección. Permanente y si requiere inspecciónes periódicas. Time limit.

A que cat de daños le llamamos TIME LIMIT. Cat A. Cat B. Cat C.

Número de zona 100. Lower fuselage. Upper fuselage. Doors.

To which category is applicable SRI. Cat B repair and allowable damage. Cat C Repair and allowable damage. Cat A repair and allowable damage.

SRI informátion is used for : ADL only. Repair an ADL. Repair only.

Code 202. Lh. Rh.

Code 201. RH. LH.

Denunciar Test