option
Cuestiones
ayuda
daypo
buscar.php

DES-1241

COMENTARIOS ESTADÍSTICAS RÉCORDS
REALIZAR TEST
Título del Test:
DES-1241

Descripción:
PowerStore

Fecha de Creación: 2022/04/21

Categoría: Informática

Número Preguntas: 90

Valoración:(1)
COMPARTE EL TEST
Nuevo ComentarioNuevo Comentario
Comentarios
Denunciar Comentario
Do you have the DES-1221 PowerStore test?
Responder
FIN DE LA LISTA
Temario:

1.How many nodes are in the base enclosure?. 2 nodes configured as Active-Standby. 1 node with duel connectivity. 1 node with high availability enabled. 2 nodes configured as Active-Active.

2.Which formats are available to list alerts?. Standard, NVP, CSV and JSON. Table, XLS, CSV and JSON. Table, NVP, CSV and XLS. Table, NVP, CSV and JSON.

Refer to the exhibit. What is the result of the network configuration show for a Dell EMC PowerStore T node A management port?. VLAN 1 and VLAN 1501 pass tagged traffic. VLAN 1 passes tagged traffic, VLAN 1501 passes untagged traffic. VLAN 1 passes untagged traffic, VLAN 1501 passes tagged traffic. VLAN 1 and VLAN 1501 pass untagged traffic.

Refer to the exhibit. A Storage Administrator noticed a solid amber LED.What does this mean?. Drive identification on. Drive rebuilding. Power up. Drive faulted.

How is a defective embedded module displayed in Dell EMC PowerStore Manager?. Orange with an empty state. Orange with a faulted state. Blue with a faulted state. Blue with an empty state.

Which LED combination shows a connected and working node?. power LED: steady green fault LED: amber. power LED: blinking green fault LED: off. power LED: blinking green fault LED: blue. power: LED: steady green fault LED: off.

What is the maximum number of base enclosures in a cluster when planning a Dell EMC PowerStore T installation?. 1. 2. 3. 4.

What is the last step when adding a drive to a Dell EMC PowerStore system?. Verify the new drive is seen. Add the drive to the pool. Backup the keystore. Zero the drive.

What is a step in configuring the ToR data switches for a Dell EMC PowerStore T?. Configure a port for the discovery laptop. Create VLANs for NAS servers. Create VLAN for vMotion networks. Configure ports for management on native VLAN.

What describes the ICM and ICD networks?. Address type is dynamic and automatically reconfigured on discovery results. They are NOT encrypted. Address type is persistent throughout the life of the cluster and CANNOT to be modified. They are encrypted with IPsec.

Through which network do external hosts connect to the cluster for data access?. Management. ICM. ICD. Storage.

Refer to the exhibit. What is indicated when the circled LED on the base enclosure is illuminated amber?. Base enclosure power-on. Cluster discovery state. Cluster service mode. Base enclosure fault.

Refer to the exhibit. A Storage Administrator is troubleshooting a Dell EMC PowerStore T hardware issue. They observe that the base enclosure LED circled is blue. What does this indicate?. Base enclosure hardware is operating normally. Base enclosure has a component hardware fault. Cluster has only a single appliance. Appliance has a node in service mode.

Which network is used for internal communication?. Intra-Cluster Data. Intra-Cluster Management. NAD Network. Inter-Node Network.

A Storage Administrator notices two fans in a Dell EMC PowerStore are faulted. What describes the system behavior in this circumstance?. A five-minute timer starts upon the second fan fault and the system shuts down automatically after the timer expires. CPU clock speed is reduced by 50% to lower internal temperatures and the system continues normal operations. An increased fan speed signal is sent to the surviving fans and the system continues normal operations. Upon the second fan fault, all host I/O is terminated immediately and the PowerStore goes through the halt and vault process and shuts down.

What does the command “svc_journalctl -f -g “st_io_monitor”” do?. Retrieves log messages from the specified error and watches for re-occurrence. Ignores log messages from the specified error and re-occurring errors. Rotates the log based on the specified error. Deletes all logs before the specified error.

A Storage Administrator notices a Critical alert present in Dell EMC PowerStore Manager relating to data integrity. What action within the alert details slide-out panel is helpful in troubleshooting the problem?. Select the Gather Support Materials from Service and Support. Access the Repair Flow link to schedule a support engagement. Examine Notifications to obtain a list of corrective actions. Re-engage support through previous listed Related Events.

Which option is used when running the journalctl command to query log messages regardless of capitalization?. option --casesensitive=YES/NO. option -quotes. option -ignorecase. option --casesensitive=TRUE/FALSE.

Which Dell EMC PowerStore network uses an appliance backplane?. ICD. MPIO. Inter-node. Inter-cluster management.

What describes the power requirements for Dell EMC PowerStore?. Lower model numbered systems require less AC line current than higher model numbered systems. T models require less total power than X models. X models require less total power than T models. Lower model numbered systems require less input voltage (VAC) than higher model numbered systems.

What Dell EMC PowerStore reference provides the user access to the entire set of product documentation, knowledge base articles, and product warranty and contracts?. SolVe Desktop and Online. Dell EMC Online Support. Dell EMC PowerStore Series Product Page. PowerStore Manager in App (Offline) Help.

What describes Dell EMC PowerStore X power down?. PowerStore X node, appliance, or cluster power down is done entirely with vCenter server commands. Powering down a PowerStore X node, appliance, or cluster is done in the same manner as a PowerStore T. PowerStore X node, appliance, or cluster power down utilizes the VSi plugin to perform the needed vCenter server operations. Powering down a PowerStore X node, appliance, or cluster requires additional vCenter server commands.

While on-site installing a Dell EMC PowerStore system, the node A and embedded module fault LEDs are alternating blue and amber (blue for 3 seconds). What does this indicate?. The system is booting. Nodes are in service mode. The system is not initialized. Nodes are in degraded mode.

From where can a data collection be initiated within Dell EMC PowerStore Manager?. Appliance, node, and storage resource. Cluster, appliance, and alerts. Cluster, appliance, and event log. Node, storage resource, and alerts.

What safety equipment is critical to have on hand to avoid equipment failure before replacing any components in a Dell EMC PowerStore array?. Maintenance Kit. ESD Kit. Stabilization Kit. Rail Kit.

How can the PUHC health check results be viewed?. By accessing the Swagger UI. From syslog server. In Details of Appliances and Nodes. From management DB.

When a Dell EMC PowerStore node powers up in service mode, what are the commands and sequence used from the appliance SSH client to restore the node back to normal?. svc_rescue_state clear svc_node reboot. svc_node restart svc_rescue_state start. svc_rescue_state normal svc_node start. svc_node shutdown svc_rescue_state clear.

A Storage Administrator needs to address specific fixes within their Dell EMC PowerStore system. Which NDU software upgrade option is used for this situation?. Hotfixes. vCenter. Drive firmware. Software releases.

What is the default log collection schedule?. Weekly. As scheduled during install. Hourly. Daily.

Refer to the exhibit. What is indicated when the circled LED on an expansion enclosure is illuminated amber?. Expansion enclosure faulted. SAS bus link up. SAS bus link down. Expansion enclosure power-on.

Which component is only replaceable by qualified personnel?. Battery backup unit. Embedded I/O module. Memory module. 4-Port mezzanine card.

Refer to the exhibit. What type of cable is used for the ToR switch configuration shown for the S5248F-ON switches?. 10 GigE Cat 6 Ethernet RJ-45. 25 GigE Twinax. 100 GigE QSFP28. 10 GigE SFP optical cable.

What is an alternative way to collect logs instead of using the Dell EMC PowerStore manager GUI?. Data Collect using Service Container. USB stick inserted into the system. Data Collect using vCenter. Discovery Utility.

What are the recommended number of network switches in a Dell EMC PowerStore T environment?. 1. 2. 3. 4.

A Storage Administrator has an existing single appliance Dell EMC PowerStore 3000T cluster. An additional PowerStore 9000T has been purchased to add into the existing cluster. How does the administrator proceed?. Additional VLTi links on the ToR switching must be configured for the 9000T to support the increased inter-switch network load. Add the new 9000T appliance into the cluster per the procedure; mixed models of the same type are supported. Remove two of the four NVMe NVRAM drives from the 9000T the caching configuration of all clustered appliances must match. The new appliance cannot be added to the cluster; appliance model and type must match when clustering appliances together.

What describes the SAS cabling when adding an expansion enclosure to a Dell EMC PowerStore, for each node and expansion enclosure side?. SAS cabling goes from existing A ports to new ports. At the last enclosure, SAS cabling returns from the A ports to the originating node’s B ports. SAS cabling goes from existing A ports to new ports. At the last enclosure, SAS cabling returns from the A ports to the alternate node’s ports. SAS cabling goes from existing ports to new A ports. At the last enclosure, SAS cabling returns from the ports to the alternate node’s A ports. SAS cabling goes from existing ports to new A ports. At the last enclosure, SAS cabling returns from the ports to the originating node’s A ports.

During an emergency event an ESD-Kit is unavailable for FRU replacement. How can the work proceed?. If FRU does not contain ESD-Kit, continue without it. Order “Emergency ESD-Kit” ASAP. Follow precautions described in the “Emergency Procedure”. Use package material to build “provisional ESD-Kit”.

.A Storage Administrator has just installed PSTCLI on a Linux client. The administrator is unfamiliar with the PSTCLI command list. How can the administrator get a list of all PSTCLI commands from the cli> prompt?. Type the <Ctrl>+keys together. Press the <Tab> key. Use the show all command. Use the help all command.

A Storage Administrator needs to add drives to a base enclosure of a Dell EMC PowerStore 7000T system. The system currently contains 10 750 GB NVMe SCM drives. Which drive configuration maximizes the base enclosure capacity?. 11 15360 GB NVMe SSD drives in slots 10 - 20. 13 15360 GB NVMe SSD drives in slots 10 - 22. 11 750 GB NVMe SCM drives in slots 10 - 20. 13 750 GB NVMe SCM drives in slots 10 - 22.

What is the maximum number of expansion enclosures that a single Dell EMC PowerStore appliance supports?. 2. 3. 4. 6.

What describes Dell EMC PowerStore X front-end cabling?. Uses internal VMware virtual switching and does not require a management network. Storage and management use the same LACP bonded cable connection. Uses VLTi data switch interconnectivity to support vMotion networks. Management and discovery use the same cables and connections as storage.

A Storage Administrator wants to upgrade a two appliance Dell EMC PowerStore cluster. Which Commit options need to be chosen to have all appliances upgraded in the last step?. Appliance, Cluster. Appliance, Appliance. Cluster, Appliance. Cluster, Cluster.

What method is used to power down a Dell EMC PowerStore system in a true emergency situation?. Run svc_node shutdown. Power Down Cluster in PowerStore GUI. Turn off the cabinet switches. Remove base enclosure power cables.

How is a service laptop IP configured to connect to the Service LAN port of a Dell EMC PowerStore node?. Static IP: 128.221.1.249 and netmask: 255.255.255.0. Obtain IP address from DHCP on PowerStore. Static IP: 169.254.1.249 and netmask: 255.0.0.0. Leave IP address and netmask unconfigured.

Which reference source provides service information and FRU procedures for the Dell EMC PowerStore?. SolVe Tool. Dell EMC PowerStore Product Page. PowerStore Manager help. DELL EMC Online Support.

A Storage Administrator ran a PSTCLI command on a Linux host. The error " -bash: pstcli: command not found" appears. How is the problem resolved?. Add the installation directory to the PATH variable on shell initialization file. Install in default directory /opt/dellemc/pstcli-version/bin/. Add /opt/dellemc/pstcli/bin/in PSTCLI.sh. Run rpm -ihv pstcli to reinstall the PSTCLI software on the Linux host.

A Storage Administrator is adding an appliance into an existing Dell EMC PowerStore T cluster. What is different about the management network configuration for the new appliance compared to configuring an initial appliance for the cluster?. All the needed management IP addresses for the new appliance must be pre-configured on the cluster. Additional appliance does not require a cluster management IP address. Additional appliance inherits all its management IPs from the existing appliance. All the needed management IP addresses for the new appliance are auto-generated by the cluster.

Which number in the code-naming schema represents a beta distribution?. 8. 6. 4. 5.

Refer to the exhibit. A Storage Administrator noticed a drive LED blinking blue. What does this indicate?. Is faulted. Access activity. Power up. Identification is on.

A Storage Administrator needs to connect through SSH to run svc commands. How is the SSH session configured?. Appliance IP address using port 22. NAS server IP address using port 26. NAS server IP address using port 22. Appliance IP address using port 26.

What is the result of setting a VLAN ID of 0 on a network when running ICW for Dell EMC PowerStore?. Network will pass tagged traffic. Static route is set. Network will pass untagged traffic. Default route is set.

Which component is an FRU?. DIMMs. Embedded IO Module. Nodes. Battery Backup Unit.

What does the output of the PSTCLI command “nas_server show” display from a Dell EMC PowerStore T?. If NAS servers are present if they are either NFS or Licensed. Memory utilization and thread count for NFS NAS servers. If NAS servers are present and if they are either Started or Degraded. SIDs of SMB NAS servers joined to the AD Domain.

Which account credentials are needed to run diagnostic commands?. root. service. console. admin.

For what is the “svc_container_mgmt status CP” command used?. Clears the Control Path audit log. Resets the Data Path root access. Checks the status of the Control Path. Checks the status of the Data Path.

What is the reason for the best practice of leaving 2 Us of space at the bottom of the rack when racking Dell EMC PowerStore systems?. Provide better rack stability. Provide cooling air intake. Leave room for serviceability. Leave clearance for wheel roll.

What is the alert severity if the license expiration date is within a week?. Warning. Minor. Major. Information.

Which component is hot-swappable?. SFP. Fan. BBU. Expansion IO module.

Refer to the exhibit. What is the result of the network configuration shown for a Dell EMC PowerStore T?. Interfaces are configured for remote replication traffic. Interfaces are configured for PowerStore discovery traffic. Ports 1/1/55 and 1/1/56 are added to a new LACP domain. Ports 1/1/55 and 1/1/56 are added to the VLTi domain.

Refer to the exhibit. Which column indicates the master appliance?. IP Address. Model. Service Tag. Mode.

While on-site troubleshooting a Dell EMC PowerStore system, the node embedded module fault LED is blinking blue and amber alternating at one second intervals. What does this indicate?. Node is in degraded mode. Node is booting. Node is on service mode. System is not initialized.

Which component is a CRU?. Base enclosure. Expansion enclosure. Battery Backup Unit. Nodes.

How many fan module failures can a node tolerate?. 0. 1. 2. 3.

When planning for a Dell EMC PowerStore T implementation, how many IP addresses are required for the storage network?. 2. 1. 3. 4.

Which port is used to SSH from one Dell EMC PowerStore appliance to another?. 22. 26. 443. 21.

In an unpopulated rack, at what U mark is the base enclosure racked?. 3. 4. 2. 1.

What is achieved when the Rapid Spanning Tree Protocol (RSTP) is enabled on a Dell EMC PowerStore network configuration?. Redundant connectivity between data switches. Communication between data switches and management switch on PowerStore T. Management between appliance and vCenter on PowerStore X. Fault tolerance between appliances in a PowerStore cluster.

Which network traffic is encrypted using IPsec?. OOB network. ICD network. Inter-node network. ICM network.

How is a defective DIMM displayed in Dell EMC PowerStore Manager?. Orange with an empty state. Blue with a faulted state. Orange with a faulted state. Blue with an empty state.

The “svc_rescue_state list” shows a node in service mode. How can the node be returned to normal mode?. svc_rescue_state normal. svc_rescue_state clear. svc_rescue_state exit. svc_rescue_state quit.

Which type of device is supported in expansion enclosures?. NVMe SCM. NVMe SSD. NVMe NVRAM. SAS SSD.

What does the output of the command “svc_diag list --basic” show?. Failover status. Master_appliance_ID. License status. Boot mode.

What is a step in configuring the ToR data switches for a Dell EMC PowerStore X?. Configure a port for the discovery laptop. Create VLANs for NAS servers. Create node A port-channel. Configure LACP uplink to management switch.

What guidance must to be considered for Service LAN port access of a Dell EMC PowerStore appliance?. Always connect multiple appliances to the same hub or switch. Never connect multiple appliances to the same hub or switch. Never connect the Service laptop directly to the appliance Service LAN port. Always removed the management port connections on the appliance.

A Storage Administrator needs root access. What command needs to be run?. svc_inject generate-key --root. svc_inject -root. sudo service. su - root.

A Storage Administrator encounters a Snapshot issue on a Dell EMC PowerStore X system. The administrator engages support and they determine the Snapshot issue is a known code bug within the OS version of PowerStore code. How can support address the problem in a timely manner?. Disable the Snapshots feature to avoid encountering the code bug. Upgrade the Snapshot portion of code within the OS. Upgrade the PowerStore with a hotfix that corrects the code bug. Wait for a new full OS release that corrects the code bug.

Refer to the exhibit. What Dell EMC PowerStore ToR front-end cabling is shown?. OOB Management. VLTi interconnectivity. Core switch uplink. Management and discovery.

While on-site installing a Dell EMC PowerStore T system, the node A embedded module management Ethernet port link LED is off. What does this indicate?. Network connection is established. No network connection is established. Port speed is 1 GB/s. Port speed is 10 GB/s.

Which Dell EMC PowerStore model reserves the last two slots of the base enclosure for NVMe NVRAM?. 3000. 5000. 7000. 9000.

Under which condition does the Dell EMC PowerStore equipment in the rack require additional stability?. Low temperatures. Unstable humidity. Unstable environments. High temperatures.

What is the protocol used for the storage network?. FC. NFS. SMB. iSCSI.

Refer to the exhibit. What is indicated when the circled LED on the node embedded module is illuminated solid amber?. System is booting. Module is faulted. Node is faulted. Cluster is uninitialized.

When looking at the base enclosure front view, what does a solid amber drive LED indicate?. Discover new drive. Rebuild activity. Faulted drive. Normal activity.

What describes Dell EMC PowerStore heat dissipation?. X systems have higher heat dissipation specifics than T systems. Higher model numbered systems have lower heat dissipation specifications than lower model numbered systems. T systems have higher heat dissipation specifics than X systems. Lower model numbered systems have lower heat dissipation specifications than higher model numbered systems.

Which component can be replaced while the Dell EMC PowerStore is up and running?. 4-Port Mezz card. SFP. M.2 Device. LCC.

In which step of the ICW can the configuration details be exported?. License Configuration. Support Assist. Cluster Details. Cluster Configuration.

Which experienced administrator role needs to address a warning about configuring VLTi?. Storage. VMware distributed switch. Network. NAS.

A Storage Administrator notices a Major alert present in Dell EMC PowerStore Manager relating to data protection. What action within the alert details slide-out panel is helpful in troubleshooting the data protection problem?. View the Associated Events for earlier related alerts. Examine Notifications to obtain a list of corrective actions. Acknowledge the alert to clear and resolve the problem. Access the Repair Flow link to schedule a support engagement.

What does the command “svc_journalctl | grep ‘Mar 25 23:00’” do?. Ignores log messages from the specified date. Retrieves log messages from the specified date. Deletes all logs before the specified date. Rotates the log based on the specified date.

During Dell EMC PowerStore startup, both appliance nodes have rebooted in service mode. What must be done first to avoid management software conflicts?. Reboot node B. Clear the boot mode. Disable node B boot mode. Return node A to normal mode.

Denunciar Test