Temario:

!!In which VxRail models is the iDRAC NIC Selection Setting set to Dedicated?. P570, V570, and S570 only. E560 and G560 only. P570, V570, S570 and G560. E560, P570. V570, and S570.

!!!What is the purpose of the As-Built Configuration Generator?. Create the customer deliverable documentation of the Dell EMC product/solution implementation. Provide advanced control grouping for Stretched clusters. Capture and generate the installation workflow for review in the event of a failed deployment. Keep a record of all spare nodes, not yet added to a VxRail Cluster.

!!!A system administrator wants to check the version of the VxRail Manager Plug-In. Where can this be done?. vSphere Client > VxRail Cluster > Configure> VxRail Support. vSphere Client > Menu Administration > Client Plug-Ins. vSphere Web Client > Menu Administration > Client Plug-Ins. VxRail Manager URL > System Health > Client Plug-Ins.

!!!You have provisioned a virtual machine on a VSAN datastore, VSAN creates a set of objects composed of multiple components. What is the maximum supported size of a component?. 128 GB. 255 GB. 256 GB. 512 GB.

!!What is the default VLAN ID of the Private Management VLAN network on a VxRail 4.7.x node?. 0. 1. 3939. 4095.

!!!When running the VxRail SmartFabric Personality profile script, what is preserved from the initial default Full Switch mode configuration?. Management VLANS. VLAN 1. Uplink Breakouts. ICL Uplinks.

!!In which VxRail model is the IDRAC NIC Selection Setting set to LOM1?. G560. G410. E560. S570.

!!!A Dell EMC solutions architect has converted the VxRail PEQ to Customer Mode. They have engaged with the customer to input information about the VxRail networks IP address, subnet mask, gateway, and VLAN ID details. In which section would the customer input this information?. System Information. Physical Network. Es× Host Details. Virtual Machines.

!!!A VxRail Stretched Cluster deployment will have E560F nodes. The Cluster must allow local protection with both erasure coding options at either site. What is the minimum node configuration?. 3+3 nodes. 4+4 nodes. 6+6 nodes. 8+8 nodes.

!!!You are validating that a network environment is ready for a VxRail deployment. What types of DNS records must be created for VxRail components before Implementation can begin?. Forward (A) records only. Forward (A) records and Reverse (PTR) records. NS records and Reverse (PTR) records. Reverse (PTR) records only.

!!Beginning with VxRail version 4.7, which product license option has changed?. VSAN. vCenter. VMware Log Insight. vSphere.

!!What is the object space reservation for the default VXRAIL-SYSTEMSTORAGE-PROFILE?. 0%. 50%. 75%. 100%.

!!!!A Secure Remote Services deployment on a VxRail system with external vCenter fails with "Invalid target datastore specified". What action is required to resolve this problem?. Manually deploy Secure Remote Services. Retry the deployment through the retry button. Ensure DNs is able to resolve the SRS/VE VM hostname. Restart vCenter services and retry the deployment.

!!!What is the correct order of steps to expand a Dell Power Edge based V>Rail Cluster?. Add the new node to the existing cluster. Power on the new VxRail node. connect to the vsphere client. verify that the loudmouth service is running. verify that the new vxrail node has been discovered.

!!What log file provides details about anything done on the VxRail system, including installation?. Icm.log. powertools.log. mystic.log. marvin.log.

!!A VxRail solution will be deployed with the embedded VCenter and Log Insight. Prior to deployment, DNS records must be created for which entities?. vCenter Server, ESXi hosts. VxRail Manager, and Log Insight only. vCenter Server, Platform Services Controller ESXi hosts, VxRail Manager, and Log Insight only. ESXi Hosts, VxRail Manager Log Insight, and iDRAC only. vCenter Server, Platform Services Controller ESXi hosts, VxRail Manager, Log Insight, and iDRAC.

!!!Refer to the exhibit What does the Fabric ID shown on the GUI actually represent for the switch cluster personality profile?. Domain ID. Cluster ID. SmartFabric ID. Fabric ID.

!!What are some of the items contained in a VxRail As-Built Configuration report?. Security updates Support matrices Firewall Ports listing. Security updates Upgrade path Firewall Ports listing. System configuration Firewall Ports listing Support matrices. System configuration Support matrices Upgrade procedures.

!!What does the VxRail NVT validate when only Network Services Validation is enabled?. VLAN configuration, NTP and DNS settings. IP address conflicts, NTP and DNS settings. VLAN and LACP configurations. VLAN and STP configurations.

!!You are configuring SmartFabric Services on a VxRail running version 4.7.x. What is the maximum number of separate vCenter instances that an OMNI plug-in can be registered with in a single fabric?. 1. 2. 5. 10.

!!What data protection methods are included with the VxRail Appliance?. Stretched Clusters NetBackup vSphere Replication. Stretched Clusters RecoverPoint for VMs vSphere Replication. vSphere Replication RecoverPoint for VMs Avamar. RecoverPoint for VMs Data Domain Stretched Clusters.

!!What is the primary use of the VxRail PEQ Addendum?. Specifying Dell EMC- deployed switches and Stretched Clusters. Generating the NVT/FDC JSON configuration file. Deploying customer provided, non-Dell EMC network switches. Manually configuring VxRail Manager.

!!By default, which block of IP addresses provided to the VxRail First Run Wizard may contain non-contiguous addresses?. ESXI Host. VSAN. NTP Servers. VSphere vMotion.

What is a consideration when adding nodes to a VxRail G Series chassis?. G560 and G410 nodes are permitted in the same chassis. In a full G Series chassis, all nodes must have 10GbE ports. Hybrid and All-Flash nodes are permitted, if in different chassis. All nodes in a G Series chassis must be identical.

Which vSAN rules are configured for the VXRAIL-SYSTEM-STORAGE-PROFILE?. Failures to tolerate - 2 failures RAID-1 (Mirroring) Object space reservation - Thin provisioning. Failures to tolerate - 1 failure RAID-1 (Mirroring) Object space reservation - Thin provisioning. Failures to tolerate - 1 failure RAID-1 (Mirroring) Object space reservation - Thick provisioning. Failures to tolerate - 1 failure RAID-5 (Erasure Coding) Object space reservation - Thick provisionin.

Which command can be used from the VxRail Manager VM to restart the loudmouth daemon?. systemctl restart loudmouth. /usr/lib/vmware/loudmouth/bin/loudmouthd restart. /etc/init.d/loudmouth restart. systemctl restart vmware-loudmouth.

From what environment must a network administrator run VxRail network validation?. Windows PowerShell command prompt. Same subnet as VxRail Management Network. Top of Rack switches. VxRail Deployment Wizard.

What is a characteristic of the VxRail S Series node?. Form factor of 2U4N. Large form factor drives. Dense Flash disks. Form factor of 1U1N.

Where can an administrator find steps to perform a manual verification of the customer network?. Customer Simplified Form. Dell EMC VxRail Network Planning Guide. Pre-Engagement Questionnaire (PEQ). Dell Technologies SolVe Online.

Which VxRail Series is designed to support a VDI environment and requires a GPU card in each host?. S Series. V Series. G Series. P Series.

A VxRail solution will be deployed with the embedded vCenter and an external DNS At a minimum, for which components must DNS records be created?. vCenter Server Platform Services Controller, and iDRAC. vCenter Server, ESXi hosts, and VxRail Manager. vCenter Server Platform Services Controller, and VxRail Manager. ESXi Hosts, VxRail Manager and iDRAC.

A systems engineer needs to ensure that the VxRail system is healthy and any issues found are addressed prior to starting an upgrade process. Where in the vSphere Client can they review alarms and overall vSAN health?. Triggered Alarms > Issues and Alarms > All issues Triggered Alarams > vSAN > Skyline Health. Monitor > All Issues > Issues and Alarms Monitor > vSAN > Health. Triggered Alarms > All Issues > Issues and Alarms Triggered Alarms > vSAN > Health. Monitor > Issues and Alarms > All issues Monitor > vSAN > Skyline Health.

A company has recently implemented a popular date center monitoring and reporting software solution. They plan to use the solution to consolidate reporting into a single platform. What is an expected benefit of programmatically gathering VxRail information?. Perform node shutdowns and specific operations. Perform pre-checks for vSAN health. Automate iDRAC firmware management and status. Obtain status of all running operations on a cluster.

In addition to hardware monitoring, what is the purpose of the Dell PTAgent service on a VxRail node?. Hardware discovery and firmware installation. VxRail node discovery and software upgrades. BOSS upgrade and firmware installation. Hardware discovery and VxRail VIB installation.

Which two files are used to automate VxRail deployment and validate the network configuration?. Appliance JSON file PEQ data file. VxRail Configuration Portal PEQ data file. VxRail Test Plan SPEQ. Appliance JSON file SPEQ.

What environmental components of a 3-node VxRail cluster must be assigned IP addresses?. ESXi Mgmt, vCenter, Witness Traffic Separation, and iDRAC. vRealize Log Insight. vSAN, VxRail Manager, and SRS. vSAN, Witness Traffic Separation, vRealize Log Insight, and vMotion. ESXi Mgmt, vSAN, vMotion, and iDRAC.

What is the correct CLI command to collect only the vCenter logs on VxRail Manager. vc-support.sh -v. generateFullBundle.py -v. vc-support-bundle.sh -c. generateLogBundle.py -c.

An implementation engineer is deploying a new VxRail cluster What should they confirm before installing the hardware?. At least 24 in (61 cm) of clearance exists in front of and behind the cabinet. Redundant power zones exist with adequate power cables. Power distribution supports only the power rating of a single node. Service laptop is on the same IP network as the iDRACs.

What setting is used for the object space reservation in the VXRAIL-SYSTEM-STORAGE-PROFILE?. 50% Reservation. Thick Provisioning. 75% Reservation. Thin Provisioning.

A planned VxRail Stretched Cluster will have four All-Flash nodes at each site What is the recommended storage policy to ensure cross-site and local protection, using storage as efficiently as possible?. Site disaster tolerance - None - keep data on Preferred (stretched cluster) Failures to tolerate -1 failure - RAID-5 (Erasure Coding). Site disaster tolerance - Dual site mirroring (stretched cluster) Failures to tolerate - 1 failure - RAID-5 (Erasure Coding). Site disaster tolerance - Dual site mirroring (stretched cluster) Failures to tolerate - 1 failure - RAID-1 (Mirroring). Site disaster tolerance - Dual site mirroring (stretched cluster) Failures to tolerate - no data redundancy.

An implementation engineer is reviewing the customer requirements for a VxRail implementation The customer has specified noncontiguous hostnames and IP addresses What option should the engineer select in the VxRail Deployment Wizard to input the hostnames and IP addresses?. Autofill - with the correct incrementor. Advanced. Autofill - with the correct offset. Custom.

A planned VxRail Stretched Cluster will have four hybrid nodes at each site. What is the recommended storage policy to ensure cross-site and local protection, using storage as efficiently as possible?. Site disaster tolerance - None keep data on Preferred (stretched cluster) Failures to tolerate - 1 failure - RAID-1 (Mirroring). Site disaster tolerance - Dual site mirroring (stretched cluster) Failures to tolerate - 1 failure - RAID-5 (Erasure Coding). Site disaster tolerance - Dual site mirroring (stretched cluster) Failures to tolerate - No data redundancy. Site disaster tolerance - Dual site mirroring (stretched cluster) Failures to tolerate - 1 failure - RAID-1 (Mirroring).

What is a difference between vSAN Data-In-Transit Encryption and vSAN Data-At-Rest-Encryption?. Data-In-Transit Encryption: Encrypts traffic between VMs and the VxRail nodes Data-At-Rest Encryption: Encrypts traffic between VxRail nodes only. Data-In-Transit Encryption: Does not require a Key Management Server Data-At-Rest Encryption: Requires a Key Management Server. Data-In-Transit Encryption: Key Management Server must reside on the vSAN cluster Data-At-Rest Encryption: Key Management Server can reside on the vSAN cluster. Data-In-Transit Encryption: Addresses fear of media theft Data-At-Rest Encryption: Addresses fear of rogue administrators.

Match each component of the VxRail HCI System Software to its description. Upstream APIs. Local cluster management. Backend and Downstream APIs. SmartFabric Services. VMware Connectors.

A VxRail cluster 4.7.xxx environment is managed by the internal vCenter Server. An implementation engineer plans to deploy a new VxRail cluster using the existing vCenter Server instance, then use the customer-supplied VDS to manage both VxRail clusters. What must be done?. Migrate the internal vCenter Server to an external vCenter Server, then merge the PSC. Upgrade the VxRail version from 4.7.xxx to 7.0.000. Migrate the internal vCenter Server to an external vCenter Server, then upgrade the VxRail 4.7.xxx to 7.0.100. Upgrade the internal vCenter Server to version 7.0.

A VxRail Manager VM must be configured as follows: * IP address: 192 168.10.16 * Net mask: 255.255.255.0 * Gateway: 192 168 10 254 Which command must be used?. vxrail-network-config --ip 192 168 10.16-netmask 255.255.255.0-gateway 192 168 10.254. vxrail-prrmary -config --ip 192 168 10 16 -netmask 255 255 255 0 -gateway 192 168 10 254. vxrail-primary -config --vxrail-address 192.168.10.16 --vxrail-netmask 255.255.255.0 --vxrail-gateway 192.168.10.254. vxrail-network -config --vxrail-address 192.166 10 16 --vxrail-netmask 255 255.255 0 --vxrail-gateway 192.168.10.254.

What is a requirement for the vSAN Data-at-Rest Encryption?. All-Flash or AII-NVMe VxRail. VxRail with at least 3 nodes. External Key Management Server. External customer provided vCenter.

An implementation engineer needs to validate the VxRail network configuration. Where can they obtain the NVT for VxRail?. Dell Technologies Central. Dell Technologies Information Hub. Dell VxRail Expert Channel. Dell VxRail Fast Pass.

An implementation engineer is in the validation phase of a VxRail deployment with two Dell EMC ToR switches. Which command should they run on each of the ToR switches to validate that Link Aggregation has been configured according to Dell best practices for VxRail node interfaces?. show network-policy profile. show interface status. show port-channel summary. show interface.

What is a supported witness configuration for a 3+3+1 VxRail Stretched Cluster?. vSAN Witness appliance with customer provided license. Physical ESXi host with included cluster license. Physical ESXi host with multiple VxRail clusters as witness. vSAN Witness appliance or a physical ESXi host.

What is a consideration when performing a VxRail software upgrade from version 4.7.xxx to version 7.0.xxx?. External vCenter server must be upgraded after the VxRail is upgraded. vCenter Server requires a temporary IP address on a different subnet before the upgrade. Secure boot must be enabled on the ESXi hosts for a successful upgrade. VxRail Manager VM must be changed to the default name to avoid an upgrade failure.

What is the correct CLI command to collect only the VxRail Manager logs?. generateFullBundle.py -c. vm-supportsh -c. generateLogBundle.py -v. vc-support sh -v.

What is validated by running the Proactive VM Creation test in vCenter on a VxRail cluster?. vSAN operates successfully. Network firewalls are configured correctly. vSAN has sufficient storage capacity. Network performance is sufficient.

What is a consideration when expanding a VxRail cluster? (Choose two.). Mixing of All-Flash and all-NVMe nodes in a cluster is not allowed. Expanding a cluster to 64 nodes requires a 25 GbE network. G Series clusters can be expanded only with G Series nodes. 1 GbE must be hybrid and single processor node type.

According to the VxRail PEQ Engagement Details worksheet, links to what resources should the SE send to the customer?. VxRail vCenter Server Planning Guide Network Validation Tool. VxRail vCenter Server Planning Guide VxRail Network Planning Guide. VxRail QuickStart Guide VxRail Network Planning Guide. VxRail QuickStart Guide Network Validation Tool.

A company has multiple VxRail systems installed at geographically dispersed data centers They want to upgrade all their VxRail systems to the latest release- Before the upgrade, they want an inventory report of all the VxRail systems which shows the current health status and versions of all installed VxRail components. What should be used to meet these requirements?. Mitrend VxRail Log insight. VxRail Plugin for vCenter Server DRM Services. itrend Live Optics. VxRail Plugin for vCenter Server VxRail API.

For which VxRail models must the iDRAC NIC Selection be set to Dedicated?. D, G, P, S, and V Series. E, P, S, and V Series only. D, E, P, S, and V Series. D, E, and G Series.

What is the maximum number of supported nodes in a VxRail Stretch Cluster?. 16. 30. 32. 64.

A VxRail Test Plan has been completed What is the protocol for recording the results'?. With the implementation team, complete and document each test, test date, and a screenshot of results. In front of a customer, complete each test and document the test date. With the implementation team, complete each test and document the test date. In front of a customer, complete and document each test, test date, and a screenshot of results.

An infrastructure system audit will begin in two weeks All data center devices will be checked to ensure they contain the installed patches and configurations. A system engineer will update the VxRail hosts with the latest patches and remediate security vulnerabilities. What troubleshooting resource can a user receive from Dell and use proactively to help perform the remediation tasks?. KB articles. SolVe Online. Log files. Advisories.

An implementation engineer logs in to the vSphere Client of a recently deployed VxRail cluster. They want to review the firmware versions on the VxRail nodes. Which view should they use to gather this information?. Hosts and Clusters > VxRail Host > Configure > VxRail > iDRAC Configuration. Host and Clusters > VxRail Host > Monitor > VxRail > Physical View. Hosts and Clusters > VxRail Cluster > Monitor > VxRail > Appliances. Hosts and Clusters > VxRail Cluster > Configure > VxRail > System.

What must be used when deploying VxRail with a customer-supplied VDS?. Deployment Wizard using the configuration file method. Deployment Wizard using the step-by-step method. VxRail API with configuration file. VxRail PowerShell SysBringUp Module.

An implementation engineer is configuring External SRS. Where can they find the installation files for SRS VE?. VxRail Support Matrix. VxRail Manager. SolVe Online. Dell Support Page.

A systems engineer is performing a VxRail upgrade in a VMware Horizon VDI cluster All hosts are put in Maintenance Mode. What action does the engineer need to perform on each host once the upgrade has been completed?. From the Connection Server run IcMaintcmd to delete the parent VMs and exit Maintenance Mode for each host. From the Connection Server, run IcMaintcmd to take the hosts out of Maintenance Mode and reboot them. Set the InstantClone Maintenance annotation value to the original value. Set the InstantClone Maintenance annotation value to 2.

Which service determines the primary node after powering on the VxRail nodes during the deployment of a VxRail cluster?. Loudmouth. Election. Marvin. Mystic.

A VxRail 7.0.100 environment is managed by the internal vCenter Server. The customer asks the implementation engineer to deploy a new VxRail cluster using the existing vCenter Server. What should the response of the engineer?. Not supported for internal vCenter Server. Not supported on VxRail software 7.0.100. Supported by neither the internal vCenter Server nor external vCenter Server. Only supported on VxRail software 4.7.xxx.

Which vSAN feature requires an All-Flash cluster?. Deduplication and compression. Data-at-Rest Encryption. Data-in-Transit Encryption. Storage Policy Based Management.

Which requirement must be met when expanding a 3-node VxRail G560F cluster with a fourth G Series node in the same chassis?. PCIe network card must be added to all nodes. Node requires only the same drive configuration. Node hardware must be identical to the other three nodes. New node must be at the same VxRail version as existing nodes.

3 What is a valid 2-node VxRail cluster configuration?. 2x 10 GbE and 2x 25 GbE in a switch configuration and external vCenter. 2x 1 GbE and 2x 10 GbE in a direct-connect configuration and external vCenter. 2x 1 GbE and 2x 10 GbE in a switch configuration and internal vCenter. 2x 10 GbE and 2x 25 GbE in a direct-connect configuration and internal vCenter.

An implementation engineer is deploying a VxRail cluster with the VxRail Deployment Wizard Which user accounts must be defined for VxRail Manager?. VxRail Manager root account vCenter service account. VxRail Manager root account VxRail Manager service account. VxRail Manager service account vCenter service account. vCenter root account VxRail Manager service account.

An implementation engineer is expanding an existing VxRail S Series cluster with an additional node. The version of the node is not at the current cluster level but is compatible. What procedure would result in the quickest node addition?. RASR Factory Image Upgrade. Factory Reset. VxRail Node Imaging Management. Compute node expansion.

The VxRail Deployment Wizard is being used on a VxRail cluster with a customer-supplied VDS. Which settings must be used to ensure successful installation?. Use the VxRail vCenter Server Upload a configuration file (JSON). Join an external vCenter Server Use the step-by-step method. Use the VxRail vCenter Server Use the step-by-step method. Join an external vCenter Server Upload a configuration file (JSON).

A company needs to enable vSphere GPU capabilities on their VxRail cluster. To do so, they need to purchase a specific entitlement. What licensing satisfies this requirement?. vSphere Enterprise Plus. vSAN Enterprise Plus Edition. vSAN Advanced Edition. vSphere Standard.

During the activation of Internal SRS, the implementation engineer receives a message that the deployment has failed What is a possible cause?. SRS VE Gateway on the same subnet as the VxRail Manager. VxRail status already set to installed' in IB database. Site ID mismatch between the IB database and the SRS Wizard. Witness Gateway not configured following Dell best practices.

Match each VxRail, data protection solution with its functionality. PowerProtect. Stretched Cluster. Recoverpoint for VM. vSphere Replication.

Which VxRail model can only be installed with static rack rails?. D Series. P Series. S Series. G Series.

An implementation engineer is expanding an existing VxRail E Series cluster with an additional node The version of the node is not at the current cluster level and is not compatible What action must be performed before adding the node?. Order node with correct image. RASR Factory Reset. RASR Factory Image Upgrade. Compute node expansion.

How should an administrator manually validate the DNS readiness of a customer network?. Run a traceroute to the DNS server. Generate a Network PEQ. Ping the default gateway of the management VLAN. Run nslookup on server FQDN and IP.

A VxRail D560 cluster was delivered six months ago and now needs to be prepared for installation with the target code. What is the correct method to complete the task?. Boot into RASR ISO and perform a RASR Reset. Boot into RASR USB and perform a RASR Reset. Boot into SD card and perform a Factory Reset. Boot into RASR ISO and perform a Factory Reset.

Match each VxRail API request with the information to be retrieved. get/v1/vc/mode. get/v1/system/initialize/status. get/v2/system. get/v1/system.

What is the minimum number of VxRail nodes required for a vSAN storage policy with RAID-6 (Erasure Coding)?. 4. 5. 6. 7.

For which typical activity would the Full data migration setting be used when placing a VxRail host into maintenance mode?. Temporary maintenance. Rebooting a single ESXi host. Shutting down an entire cluster. Permanently removing host from cluster.

What is a valid 2-node VxRail cluster configuration?. Series with 4x 25 GbE in a direct-connect configuration. Series with 4x 10 GbE in a switch configuration. Series with 4x 1 GbE in a direct-connect configuration. Series with 2x 25 GbE in a switch configuration.

A systems engineer needs to check the health of the nodes and the system VMs to prevent complications or failures during VxRail upgrades. Which tool must be used to perform the task?. VxVerify. CloudlQ. SolVe Online. VxRail ACE.

An implementation engineer is configuring the network firewall to support a VxRail installation. Where can they find the necessary firewall rules?. Network Validation Tool. VxRail Configuration Portal. As-Built Configuration Report. Rack worksheet of the Network PEQ.

An implementation engineer is working with a customer to prepare an external vCenter Server for a new VxRail deployment with the VxRail-deployed VDS. What vCenter objects must existfor a successful VxRail deployment?. Cluster and VxRail Management user only. Datacenter Cluster, and VxRail Management user. Datacenter and Cluster only. Datacenter and VxRail Management user only.

A VxRail E560F model was delivered six months ago and is now scheduled to be installed with the target code. What is the correct order of steps to complete this task?. create RASRUSB and boot from usb stick. perform factory reset and boot from boss. boot the node from the mounted RASR ISO. Install DUPs and boot from SD. Perform RASR reset and boot from SD.

A systems engineer is tasked to configure a VxRail cluster and notices that the VxRail Deployment Wizard fails to launch. The engineer discovers that the software is corrupted. What should the engineer do to address the issue?. Use the VMware Host Client and iDRAC to access the nodes for troubleshooting. Verify that the JSON file is not corrupted and has all the required values. Return the nodes to the original build state. Check vCenter and troubleshoot the build failure.

A systems engineer is deploying a VxRail cluster. They want to ensure that configuration issues can be avoided when expanding this cluster. Which actions need to be performed?. Verify VxRail nodes are racked and connected to the ToR switches Validate the network environment. Validate that no pending and unfinished jobs are running on the servers Verify that the server and storage components are working properly. Validate that the latest updates and patches are installed in the system Validate that no pendingand unfinished jobs are running on the servers. Verify the configuration settings initially captured in PEQ Validate the storage environment.

A VxRail API request has been executed and the user account does not have vCenter privileges to perform the task What code is returned?. 200. 207. 403. 500.

Once a VxRail cluster has been acquired, what is the correct sequence of steps to deploy it?. Configure the cluster. Conduct project kick-off meeting. Validate customer readiness. Gather and document customer configuration requirements. Install VxRail hardware.

What Is a supported method for racking nodes for a new VxRail deployment?. In the rack hosting the network equipment used to manage the iDRAC. With PDUs connected to 120v single phase 5-amp electrical circuits. Starting with node 1 at the top of the rack. With server exhaust facing the cold aisle.

In a VxRail Stretched Cluster deployment of 8 nodes on between sites?. Primary to Witness site RTT: < 250 ms Secondary to Witness site RTT; < 250 ms Primary to Secondary site RTT: < 5 ms. Primary to Witness site RTT: < 150 ms Secondary to Witness site RTT: < 150 ms Primary toSecondary site RTT: < 10 ms. Primary to Witness site RTT: < 200 ms Secondary to Witness site RTT: < 200 ms Primary to Secondary site RTT: <: 5 ms. Primary to Witness site RTT: < 200 ms Secondary to Witness site RTT < 200 ms Primary toSecondary site RTT: < 10 ms.

What are the requirements for a customer-supplied VDS in a VxRail deployment?. 4 or 8 uplinks Port groups for Discovery, Management, vMotion, and vSAN only. 2 or 4 uplinks Port groups for Discovery, Management, vMotion, and vSAN only. 2 or 4 uplinks Port groups for Discovery, Management vCenter Server, vMotion, and vSAN. 4 or 8 uplinks Port groups for Discovery, Management, vCenter Server, vMotion, and vSAN.

What guideline should be followed when planning bandwidth between sites hosting VM objects and the witness nodes?. 1500 MTU on the VSAN vmkernel interface. 5 ms with a recommended minimum bandwidth of 10Gbps. 2 Mbps for every 1000 objects on the vSAN. 500 ms roundtrip (< 250 ms one way).

What is the recommended format for host names when using the VxRail Deployment Wizard for an External vCenter solution?. FQDN for vCenter Server Host name for VxRail Manager. Host name for both vCenter Server and for VxRail Manager. FQDN for both vCenter Server and for VxRail Manager. Host name for vCenter Server FQDN for VxRail Manager.

An implementation engineer is tasked with setting up RecoverPoint for VMs on a new 4-node E Series VxRail duster How many VMs are licensed to be protected on the cluster?. 5. 10. 20. 25.

4 Which vCenter object is created automatically when deploying VxRail with an external vCenter Server?. Resource Pool. Cluster. Datacenter. VxRail Management user account.

Match each IDRAC Maintenance page tab to its description. Diagnostics. Lifecycle Log. Job Queue. Support Assist. Troubleshooting.

Which VxRail model(s) has a non-mirrored IDSDM?. D560/F. All G Series. S570. All E Series.

What is the correct sequence of steps to perform a RASR Factory Reset using an SD card?. Access iDRAC and launch virtual console to the VxRail node. Boot the node from the internal SD card. Select "F" - Factory reset. Ack caution message, type disconnected to proceed. Quit the RASR menu, and reboot the system.

From what location should NVT for VxRail be run?. Jump server on a different network. Workstation on the same network as VxRail Manager. VxRail network Top of Rack switch. Laptop connected to the first VxRail ESXi node.

What code is returned when a VxRail API request is executed successfully?. 207. 200. 400. 500.

Which command is used to restart the Loudmouth process on an ESXi node?. /usr/IibAmiware/loudmouth/bin/loudmouthd restart. systemcti restart loudmouth. /etc/int.d/loudmouth restart. systemcti restart vmware-loudmouth.

What is the maximum number of supported nodes for a VxRail cluster running on a 1 GbE network?. 4. 8. 16. 32.

An implementation engineer places a VxRail node into maintenance mode using the Ensure accessibility setting What is the engineer likely planning to do?. Extensive maintenance. Temporary maintenance. Permanent removal of host from cluster. Shutdown of an entire cluster.

A VxRail cluster is being deployed in a DMZ environment. What is the recommended deployment option?. External vCenter Server with customer-supplied VDS. External vCenter Server with VxRail-deployed VDS. Internal vCenter Server with internal DNS. Internal vCenter Server with external DNS.

How must node ports on Dell EMC ToR switches be configured when the Spanning Tree Protocol is enabled in an environment?. In Port-Channel mode. In Forwarding status. As edge ports. As access ports.

An implementation engineer is tasked with setting up RecoverPoint for VMs on a single G Series chassis. How many VMs are licensed to be protected on the cluster?. 5. 10. 15. 20.

What is the basis used for VMware vSAN licensing?. TB capacity per node. TB capacity per cluster. Per disk group. Per CPU socket.

When preparing to generate an As-Built Configuration Report, it is determined that the VxRail Configuration JSON file was not saved from the Deployment Wizard. What actions must be taken to retrieve the JSON file?. SSH to the VxRail Manager VM with the mystic user SU to root Go to the /opt/VxRail/config directory SCP the initial-config json file to a local location. Log in to vCenter with the vSphere Client with the vCenter Server Management user Go to Monitor > VxRail > Last Configuration Data Sent Use the Download option. Open an FTP connection to the VxRail Manager VM with the mystic user Go to the/var/lib/vmware-marvin directory GET the config-initial json file. Log in to vCenter with the vSphere Client with the vCenter Administration user Go to Configure >VxRail > System Use the Product Documentation option.

What is the minimum number of VxRail nodes required for a vSAN storage policy with RAID-5 (Erasure Coding)?. 3. 4. 5. 6.

Match each VxRail configuration with its related characteristic. External vCenter with customer-supplied VDS. Internal vCenter with internal DNS. Internal vCenter with external DNS. External vCenter with external DNS.

A customer has decided that they will be using the Spanning Tree protocol in their Dell EMC ToR switches How should the switch ports used for VxRail be configured to achieve a successful deployment?. Set the port type to edge. Enable link aggregation for all ports. Set the port mode to access. Enable MLD snooping and querier.

What is validated by running the Proactive Network Performance test in vCenter on a VxRail cluster?. Latency and bandwidth measurement to the witness host. Network configuration and performance for vSAN. Network performance for virtual machines. Latency measurement between DCs for Stretched Clusters.

An implementation engineer is deploying a new VxRail cluster. What should they confirm before installing the hardware?. Service laptop must be on the same IP network as the iDRACs. At least 36 in (92 cm) clearance exists in front of and behind the cabinet. Power distribution must support the power rating of a single node. Single power zone must be used with adequate power cables.

What data protection option is included with VxRail?. vSphere Replication NetWorker. PowerProtect Software Data Domain Cloud Tier. RecoverPoint for VM vSphere Replication. RecoverPoint for VM Avamar.

According to Dell best practices, which VxRail series can be deployed in either datacenters or remote locations?. D Series. V Series. G Series. E Series.

What is a consideration when implementing a custom VDS on a VxRail cluster?. Used by multiple clusters managed by a single vCenter instance. Supported with external and internal vCenter Servers. Supports only four NIC uplinks. Supports only two NIC uplinks.

!!What is a benefit of using the VxRail REST API?. Remote upgrades of iDRAC related software only. Automated security audit of VxRail clusters. Automated log collection for VxRail clusters. Polling for vSAN performance statistics.

!!What else must be enabled on the switch ports used for VxRail to achieve a successful deployment?. IPv4 Multicast. IGMP Snooping. IPv6 Unicast. PortFast.

!!You have determined that you need to execute a RASR factory upgrade of a VxRail v4.7.1xx node. You download the RASR ISO from the Dell Support site. What is the correct order of steps to finish the upgrade?. Map the RASR ISO as a virtual CD/DVD. Update Firmware. Access iDRACand launch virtual console to the VxRail node. Select R in the RASR menu. Boot the node from the virtual CD/DVD ISO.

!!You are about to perform a VxRail deployment in a Dell EMC SmartFabric configuration. What does the VxRail First Run Squire as an input when configuring the discovered SmartFabric Switch Cluster?. REST_USER password. Admin user password. Domain ID, Uplink Interfaces, and ICL interfaces. Fabric ID and switch personality mode.

!!!Dell EMC will be responsible for the configuration of ToR and Management switches for a VxRail deployment. Where should these details be documented?. VxRail PEQ Cluster Sheet. Appliance JSON file. NVT/FDC JSON file. VxRail PEQ Addendum.

!!You are ordering three All-Flash G560 nodes for a new installation. These nodes need to be connected to a ToR Dual Switch Topology. What is a consideration for this installation?. Link aggregation must be enabled on VxRail switch ports. All G560 nodes must be configured with four ports for network traffic. IPv6 Multi cast must be enabled in this environment. All-Flash VxRail models must use 25 GbE NICS.

!!Which PSC option is supported for VxRail with an embedded vCenter?. Third-party load balancers. Embedded PSC. Changing the SSO domain. Changing the SSO site ID.

!!How long does it take for the Primary node to be selected for a VxRail deployment after all nodes have been powered on?. 15 to 20 seconds. 5 to 10 minutes. 5 to 10 seconds. 15 to 20 minutes.

!!What are the categories that can be validated by the VxRail NVT?. Network Services, TOR Switches and Upstream Switches. TOR Switches and Upstream Switches only. VxRail Appliance, Network Services, and ToR Switches. VxRail Appliance, ToR Switches, and Upstream Switches.

!!What are examples of standard VxRail traffic?. VMotion, and ISCSI. Management, VSAN, and vMotion. NFS, Management, and VSAN. vMotion, iSCSI, and Management. VSA.

!!What statement accurately describes the rail types used in racking VxRail nodes?. Static rails only support the option to use a cable management arm (CMA). Sliding rails are available on all models of Dell 14G VxRail nodes except for the G560. Sliding rails are available on all models of Dell 14G VxRail nodes except for the S570. Static rails enable the VxRail nodes to be fully extended out of the rack for service.

!!Which Dell PowerEdge-based Gen14 VxRail node has a non-mirrored IDSOM?. G Series. V Series. S Series. E Series.

!!What is the minimum number of VxRail nodes required for a VSAN storage policy with FTT= 1 and FTM set to Erasure Coding?. 3. 4. 5. 6.

!!You receive the error "Invalid target datastore specified" while trying to deploy Dell EMC Secure Remote Services. What is the recommended course of action?. Delete the SRS gateway and redeploy using the manual method. Wait 10 minutes and try again. Keep the SRS gateway powered for reference and redeploy manual. Rename the MARVIN- Virtual- SAN datastore to ESRS_V. x86_64.

!!What is the maximum number of nodes in a VxRail Cluster with 25 GbE?. 32. 64. 96. 128.

!!During a VxRail 2 node Cluster deployment, what is a valid connectivity option?. 2×10 GbE. 4×25 GbE. 4 x1 GbE. 2×25 GbE.

!!Match each term to its description. SRS-VE. STP. IPv6 Multi cast. PortFast.

!!What is the correct sequence of steps used by the VxRail NVT workflow?. Remediate unsuccessful items. Import the required files into NVT. Validate the configuration. Generate the NVT JSON file.

!!What is a valid NIC selection on an All-Flash G Series Cluster in the VxRail First Run Wizard?. 2×10 GbE SFP+. 2×25 GbE SFF28. 2×10 GbE RJ45. 4×1 GbE RJ45.

!!How many nodes can be added simultaneously to an easting VxRail Cluster?. 1. 2. 4. 6.

!!A VxRail Stretched Cluster will be configured with four All-Flash nodes at each site based on the following requirements: – PFTT=1 – SFTT=1 – FTM=Erasure Coding Based on the required usable capacity, what should be the planned capacity of the design?. Single Site Capacity=200% Total Cluster Capacity=400%. Single Site Capacity= 133% Total Cluster Capacity=266%. Single Site Capacity = 100% Total Cluster Capacity= 200%. Single Site Capacity=150% Total Cluster Capacity=300%.

!!SRS does not appear to be configured properly for a given VxRail Appliance From vCenter you note that the current Dell EMC Secure Remote Services status appears to be enabled and connected. The customer maintains that the configuration is not correct. What is the recommended course of action?. Disable the service and modify settings as required. Switch to an external SRS. Redeploy SRS. Engage support to help validate the SRS.

!!What command is used to restart the Loudmouth process on a VxRail node?. /usr/lib/vmware/loudmouth/bin/loudmouth restart. systemctl restart loudmouth. systemctl restart vmware-loudmouth. /etc/init.d/loudmouth restart.

!!A VxRail deployment has just been completed. The vSAN backend IOPS metrics are not available for the Cluster. What is the reason for this issue?. Data has not been populated. Health service has not be turned on. VSAN storage policy has not been assigned. Performance Service has not been turned on.

!!What is the purpose of the PTAgent on a PowerEdge-based VxRail node?. Hardware monitoring, SATADOM updating and firmware installation. Hardware discovery, hardware monitoring, and VxRail VIB installation. Hardware monitoring, SATADOM updating, and VxRail node election. Hardware discovery, hardware monitoring, and firmware installation.

!!What VxRail VSAN storage policy should NOT be changed or deleted after the initial setup?. VM Encryption Policy. VSAN Default Storage Policy. VxRAIL-STORAGE-PROFILLE. VxRAIL-SYSTEM-STORAGE-PROFILE.

!!What is the default network traffic configuration for a VxRail node with 2 x 10 GbE ports?. Management, vMotion, and Virtual Machines on Uplink1 VSAN on Uplink2. Management and vMotion on Uplink1 VSAN and Virtual Machines on Uplink2. Management and virtual Machines on Uplink1 VSAN and vMotion on Uplink2. Management Virtual Machines, and VSAN on Uplink1 vMotion on Uplink2.

!!What is a benefit of using the VxRail REST API?. Automate security audit of VxRail appliances. Remote upgrade of iDRAC related software only. Continuous polling for performance statistics. Programmatically gather VxRail system health.

!!Match each VxRail REST API status code to its associated text. 403. 200. 202. 500. 400.

!!A system administrator wants to collect the, log bundle from their VxRail, environment. What is the correct sequence of the REST API calls to accomplish this?. get /support/logs/<log_ID>. post /support/logs. get /requests/<Request ID>. get /v1/support/logs/<Log ID>/download. get /v1/support/logs.

!!Where are the vSAN logs stored?. Standard ESXi host logs. Master vSAN node. VSAN appliance VM. vCenter logs.

!!A VxRail deployment has just been completed. The vSAN backend IOPS metrics are not available for the Cluster. What is the reason for this issue?. Data has not been populated. Health service has not be turned on. VSAN storage policy has not been assigned. Performance Service has not been turned on.

!!What type of license does the Dell 4100 OS 10 Switch require to support SmartFabric Services beyond the initial trial period?. Feature specific licensing for SmartFabric Services. Full Fabric Mode licensing. SmartFabric licensing. Perpetual licensing.

!!A system administrator wants to check the version of the VxRail Manager Plug-In. Where can this be done?. vSphere Client > VxRail Cluster > Configure> VxRail Support. vSphere Client > Menu Administration > Client Plug-Ins. vSphere Web Client > Menu Administration > Client Plug-Ins. VxRail Manager URL > System Health > Client Plug-Ins.

!!You have been asked to produce an As-Built configuration report for a new Cluster. Some of the files needed will be obtained from different locations Match the file to its source location. as-built document. VxRail JSON. PEQ. VxRail xml.

!!What is the recommended storage policy to ensure cross-site and local protection using storage as efficiently as possible?. PFTT=1 SFTT=0 FTM=Erasure Coding. PFTT=1 SFTT=1 FTM=Erasure Coding. PFTT=1 SFTT=1 FTM=Mirroring. PFTT=0 SFTT=1 FTM=Mirroring.

!!You need to create a VxRail XML file to generate a VxRail v4.7.1xx As-Built Configuration report. How should you obtain this file?. Download it from the VxRail Manager GUl-Last Configuration Data Sent. Generate it from the VxRail PEQ by clicking the Create PEQ Data File button. Download it from the VxRail First Run Wizard after a successful validation. Download it from the vSphere Client VxRail plug-in-Last Configuration Data Sent.

!!What is configured by default during the initial deployment of a VxRail Cluster with All-Flash nodes?. VSAN Deduplication and Compression. VSAN storage policy with FTT=1. VSAN Performance Service. Data-at-Rest Encryption.

!!What are the four phases of VxRail Lifecycle System Management?. Deploy, Update, Monitor, and Maintain. Design, Deploy, Monitor, and Update. Design, Install, Monitor, and Update. Reset, Monitor, Maintain, and Update.

!!A system administrator wants to collect the generated log file via the VxRail REST API. Which command should they use?. PUT /support/logs/<Log_ID>/download. PUT /support/logs/<Log_ID>. GET /support/logs/<Log_ID>. GET /support/logs/<Log_ID>/download.

!!!What is an accurate statement about VxRail ToR switches?. Integrating existing switches tends to increase the costs of VxRail deployment. Dell EMC switches can be configured as part of the VxRail deployment. Link aggregation is enabled on switch ports that are connected to VxRail nodes. All VxRail ports including iDRAC must use the same Dell EMC switches.

!!Which requirement must be met when expanding a VxRail G560F 3 node Cluster with a 4th G Series node in the same chassis?. Node must be a hybrid node. Node requires only the same processor type. Node requires only the same drive configuration. Node must be identical to the other three nodes.

!!An administrator is validating nodes on a VxRail and discovers that it is not possible to add nodes. What can they use to check host connectivity?. marvin.log. PTAgent. Loudmouth. Icm.log.

!!You are in the process of setting up Dell EMC SmartFabric switches for a VXRail deployment. What happens if the script to enable the VxRail personality profile is executed without specifying the uplink and ICL interfaces?. Script runs successfully. however, the VxRail First Run validation will fail. Script uses the default values for both interfaces and runs successfully. Script fails, the interface information must be specified. Script runs in interactive mode and prompts for the required interface information.

!!During a VxRail 2 node Cluster deployment, what is a valid connectivity option?. 2×10 GbE. 4×25 GbE. 4 x1 GbE. 2×25 GbE.

!!After initial deployment of a VxRail, a system administrator realizes that the system times on some of the VxRail nodes differ from each other. What is the correct order of steps in the vSphere Client to check that NTP is active on a node?. CLICK NTP SETTINGS. Click the Configuration tab. Click the time configuration. select a host from inventory. Click edit or correct NTP Settings.

!!Match each Dell EMC Secure Remote Services related item to its description. Site ID. 9443. 22. 443.

!!What is the correct order of steps to execute a RASR factory image upgrade using a USB?. Access iDRAC, launch virtual console to the VxRail node using the Java Console plugin. Boot node from RASR USB and perform RASR reset procedure. Download RASR ISO and insert a usb disk of at least 16 GB into back of the VxRail. Select "C" in the RASR menu. Map the RASR ISO as a virtual CD/DVD then boot the node from the virtual CD/DVD/ISO.

!!You have determined that you need to execute a RASR factory upgrade of a VxRail v4.7.1xx node. You download the RASR ISO from the Dell Support site. What is the correct order of steps to finish the upgrade?. Map RASR ISO as a Virtual CD/DVD. Update Firmware. Access iDRAC and launch Virtual Console to the VxRail Node. Select "R" in the RASR menu. Boot the node from the virtual CD/DVD ISO.

!!Which vSAN feature requires an All-Flash Cluster?. Erasure Coding. Storage Policy Based Management. Data-at-Rest Encryption. VSAN Software Checksum.

!!Which components can be selected to create a log bundle in the VxRail Plug-in?. VxRail Manager, ESXI, IDRAC and Loudmouth?. VxRail Manager, vCenter, IDRAC and PTAgent. VxRail Manager, vCenter, ESXi and NVT Tool. vCenter, ESXi, PTAgent and Loudmouth.

!!You have configured the VxRail personality profile for SmartFabric and rebooted the switches. You discover that you made some errors and need to edit the profile values. What should you do?. Switch from SmartFabric to Full Switch mode and reboot both switches. Rerun the script then reboot both switches. Reboot both switches then rerun the script. Reset the entire switch fabric and rerun the script.

!!A VxRail Moel E560 Cluster will be deployed in a 1 GbE network. The system is delivered in its largest supported configuration. How much space needs to be available to rack all the VxRail nodes?. 4U. 8U. 16U. 64U.

What is the correct sequence of steps to change VxRail Manager VM network settings?. Change to root user. Establish an SSH session to the default IP address of the VxRail Manager VM. Configure required network settings for VxRail Manager VM. Log in with the mystic user account.

Which series of VxRail nodes is designed to support a large MongoDB environment that is being used for data analytics?. P Series. G Series. S Series. V Series.

For which typical activity would the No data migration setting be used when placing a VxRail host into maintenance mode?. Relocating host to remote data center. Permanently removing host from cluster. Shutting down an entire cluster. Temporary maintenance.

A system administrator attempts to use the VxRail REST API to obtain system health status for their VxRail environment. The system returns the following error code: 401. What should the administrator do to address this issue?. Use a REST API software package different than the native version of swagger. Use /v2/system instead of /v1/system. Ensure that the VxRail Manager IP address is correct. Provide vCenter credentials with sufficient rights.

An implementation engineer is deploying a new VxRail cluster. What should they confirm before installing the hardware?. Power distribution must support the power rating of all nodes. At least 24 in (61 cm) of clearance must exist in front of and behind the cabinet. Service laptop must be on the same IP network as the iDRACs. Single power zone must be used with adequate power cables.

A systems engineer notices that a VxRail host that previously appeared in a cluster within vCenter is now disconnected and is not responding. The VMs that were running on that host have been recovered on other available hosts. What initial action needs to be done to resolve the issue?. Use iDRAC to check the physical state of the nodes. Review event logs for errors and perform root cause analysis. Generate the appropriate SolVe procedure and follow it. Apply the latest updates on the host.

Which functionality is provided by the VxRail vCenter plug-in - Physical View?. LED indicator activation, initiate a disk replacement, and BIOS parameter change. BIOS and firmware versions, cluster shutdown, and initiate BIOS and firmware update. Hardware alerts, BIOS and firmware versions, and initiate a disk replacement. Hardware alerts, LED indicator activation, and initiate power supply replacement.

During deployment of a VxRail E560F cluster the data on the node becomes corrupted due to a misconfiguration. Which option in the RASR menu should be selected to ensure the quickest restart of the installation?. Factory Reset. Install DUPs. RASR Reset. Create RASRUSB.

What vSAN storage policy settings should be used to ensure adequate workload distribution and data redundancy between sites?. None - stretched cluster No Data Redundancy. None - keep data on Non-Preferred (stretched cluster) 1 failure - RAID-1 (Mirroring). None - keep data on Non-Preferred (stretched cluster) No Data Redundancy. Dual site mirroring (stretched cluster) 2 failures - RAID-1 (Mirroring).

Which log files are related to a VxRail upgrade?. loudmouth.log and marvin.log. dayone.log, short.term.log, and long.term.log. platform_svc.log and localhost_access_log.txt. lcm-web.log, lcm-migration.log, and lcm-do.log.

Match each iDRAC dashboard component to its description. Virtual Console. Maintenance Page. System Page. Task Summary. Health Information Box.

What is required to configure SRS for VxRail?. VMware ELA. Log Insight. Dell EMC Support Account. VxRail Node Imaging Management Tool.

RecoverPoint for VM has been deployed on a VxRail cluster. Data protection and management capabilities are provided within the vSphere management interface. What method within vSphere Operations should be used to ensure a successful outcome?. Air-gap data to and from the Data Center during a disaster, ensuring that the business does not suffer. Replicate data to and from SAP environment during a disaster, ensuring that the business suffers no downtime. Replicate data to and from remote offices before a disaster, ensuring that the business suffers no downtime. Back up data from remote offices before a disaster, ensuring that the business suffers minimal downtime allowing restore data.

Match each API Method to its description. Edit or update an existing resource. Retrieve a resource. Create a resource. Apply partial modification to a resource.

For which components in a VxRail environment can log files be created using vCenter vSphere Client when the VxRail Manager is unavailable?. Host operating system, vCenter server, and PT Agent. Server hardware, host operating system, and vSphere UI client. Server hardware, vCenter server, and vSphere UI client. Host operating system, vCenter server, and vSphere UI client.

Which VxRail models support the installation of rack rails with a cable management arm?. E, G, P, and S Series. D, G, P, and S Series. D, E, S, and V Series. E, P, S, and V Series.

Which activities must be completed as part of VxRail hardware installation?. Verify the time setting on each node before the first-run process Verify existence of PSNT in the DCUI Confirm that the Port Group VLAN IDs are configured as intended. Verify existence of PSNT in the DCUI Configure and use the default management network VLAN IDs Confirm that the Port Group VLAN IDs are configured as intended. Configure iDRAC for remote accessibility to perform out of band system Modify and configure the default management network VLAN IDs Confirm that the external management VLAN ID is tagged. Confirm that the external management VLAN ID is tagged Configure iDRAC for remote accessibility to perform out of band system Verify the time setting on each node before the first-run process.

Where is the VxRail Documentation Quick Reference List located?. Dell Technologies Support Page. VxRail Configuration Portal. Dell Technologies Central. Dell Technologies SolVe Online.

Dell EMC will be responsible for the configuration of ToR and Management switches for a VxRail deployment. Where should these details be documented?. VxRail Network PEQ. VxRail Appliance PEQ. Dell EMC VxRail Configuration Portal. Dell EMC Fabric Design Center.

What network setting is the optional configuration on the port group for a customer-supplied VDS before the VxRail cluster is deployed?. Assign NIC uplinks. Enable and configure NIOC. Configure NIC teaming and failover. Enable NIC teaming and failover.

How do they obtain the required VxRail XML file?. Use FTP to copy the file from the VxRail Manager VM. Download it from the VxRail Deployment Wizard after a successful deployment. Download it from the vSphere Client - VxRail Last Configuration Data Sent. Generate it from the VxRail PEQ by clicking the Create PEQ Data File button.