Voltage (electric potential) is measured: By series connecting the multimeter and the load By series connecting the ammeter to the load By connecting the multimeter in parallel to the load Electric potential cannot measured.
The device used for measuring energy is called Multimeter Wattmeter Ohmmeter Energy meter.
A multimeter can be used for measuring: Just voltage Just current Several electric variables All.
The power factor of an installation can be determined by using: A voltmeter and an ammeter A wattmeter A power meter A phase meter.
The mean value of a sinusoidal wave with maximum value of 15V is: 7,5 V 10,6 V 9,5 V 8 V.
The unit of measurement of power is: KW/h W/s Watt Joule.
The measurement of electric current is done with: A wattmeter A voltmeter An ohmmeter An ammeter.
The representation of a magnitude will depend upon: That this magnitude is analogical That this magnitude is digital The type of device utilised None.
When a conductor's continuity needs to be known: An ammeter can be used to check that current goes through the conductor A voltmeter can be used to check that there is potential difference between both ends An ohmmeter can be used to measure the resistance between both ends of the conductor A multimeter can be used in the "Continuity" mode.
An oscilloscope has shown that the period of a sinusoidal wave amounts to 10ms. The frequency of this wave will be: 0,1 Hz 10 Hz 100 Hz 1000 Hz.
The resistance of a multimeter when measuring electric currents will be: As high as possible, so as not to distort the measurement As low as possible, so as not to distort the measurement A multimeter has no internal resistance.
A wattmeter has been placed between phases 1 and 2 of a 3-phase balanced system. The value of electric power in this installation will be 3 times the power measure displayed by the wattmeter 2 times the power given by the wattmeter Two more measures are needed to calculate power A varmeter would be needed for measuring power in a 3-phase system.
In order to measure electric currents, the device must be connected: In series with the load In parallel with the load Electric currents can only be measured with clamp meters.
A clamp meter can be used for: Measuring weak alternate current magnitudes Measuring weak direct current magnitudes Measuring high alternate current magnitudes None.
The efficient value of a sinusoidal wave with maximum value of 10V is: 10V 14,14V 7,07V 6,36V.
According to the REBT, specifically to the ITC-BT 03, some of the technical means utilised by the authorised installers of the basic category are: Networks, harmonics and networks disturbances analyser Tester of operating theatre watchers and AC 3-phase power-energy analyser-recorder Earth resistance meter, isolation meter and multimeter Lux meter, ground isolation measuring electrodes and multimeter.
A Wattmeter measures, in AC systems, Apparent power Reactive power Active power None.