1-HOW MANY FIRE DETECTORS ARE THERE IN EACH THE ENGINE? A- SIX DETECTORS DUAL B- SEVEN DETECTOR SINGLE C-SIX DETECTOR SINGLE.
2-PROPULSION FIRE PROTECTION SYSTEM (PFPS) IS THE FUNCTION FOR? A-ENGINE -APU B-APU AND CARGO COMPARTMENT C- BOTH ARE CORRECT.
3- HOW MANY SQUIB HAVE THE BOTTLES OF ENGINE ? A-3 SQUIB BY EACH BOTTLE B-1 SQUIB BY EACH BOTTLE C-2 SQUIB BY EACH BOTTLE.
4- THE DETECTORS OF ENGINE ARE MADE FOR : A- TO DETECT FIRE AND SMOKE B-TO DETECT OVERHEAD CONDITION C-TO DETECT FIRE AND OVERHEAT.
5-HOW MANY BOTTLE ARE THERE FOR PURPOSE FIRE EXTINGUISHER ON ENGINE? A-2 B-ONLY ONE C-9.
6- WHERE ARE LOCATED THE ENGINE EXTINGUISHER BOTTLES? A-THE STRAT SUPPORT ON ENGINE B- PYLON C- FWD CARGO COMPARTMENT.
7-THE PROCEDURE OF FIRE EXTINGISHER OF ENGINE... A- COMPLETALLY MANUAL B-COMPLETALLY AUTOMATIC CONTROLLED BY PFPS C-BOTH ARE CORRECT.
8-HOW DETECTORS HAVE THE APU? A- 3 DETECTORS SERIAL CONNECT. B- 6 DETECTORS SERIAL CONNECT. C- 2 DETECTORS SERIAL CONNECT.
9-THE PFPS AUTOMATICALLY WILL SEND TO SHUT DOWN APU WHEN A-DETECT SMOKE OR FIRE, AFTER OF 15 SECOND AGENT EXTINGHISHER. B-DETECT FIRE, AFTER OF 15 SECOND AGENT EXTINGHISHER. C-DETECT OVERHEAT , AFTER OF 15 SECOND AGENT EXTINGHISHER. .
10- THE EXTINGHISHER OF THE APU CAN TO BE.. A-MANUAL-P40 PANEL- FIRE HANDLE P5. C-AUTOMATICALLY CONTROLLED BY PROPULSION FIRE DETECTION SYSTEM D- BOTH ARE CORRECT.
11-FIRE EXTIGUISHER OF APU WILL BE WITH: A-ONLY ONE SQUIB B-ONLY TWO SQUIB C-ONLY FOUR SQUIB.
12-Which areas also have overheat detection systems? A- APU, cargo compartments, engines, lavatories, main gear wells. B-APU, cargo compartments, engines, main gear wells. C- The engines and main wheel wells.
13-. How many detectors must sense a fire or overheat to produce an alert? A-At least one element on each channel must detect a fire or overheat condition. B-At least two element on each channel must detect a fire or overheat condition. C-At least all element on each channel must detect a fire or overheat condition.
14- If a fault is detected in one loop, will a fire or overheat still be detected? A-Yes, the remaining channel element automatically switches to single channel operation. B-No, the remaining channel will be cut automatically switches for purpose overprotection C- yes, but airplane will be AOG.
15-. How many engine fire extinguisher bottles are fitted? A-.Four, either bottles can be discharged into each engine. B. Two, either or both bottles can be discharged into each engine. C-Two, Engine left other Engine right, the bottles can be discharged only into each engine respective.
16- Will the fire bottle discharge automatically? A-Yes, after a 15 second delay to allow the fuel valve to close. B-Yes, after a 20 second delay to allow the fuel valve to close. C-Yes, after a 15 minuts delay to allow the fuel valve to close.
17-How many cargo compartment fire extinguisher bottles are there? A-7-(2HRD-5LRD) B-7-(2HBD-5LBD) C-7-(5HRD-2LRD).
18-HOW MANY IS DELAY FOR DISHARGE THE LRD ? (CARGO COMPARTMENT) 15 MIN BEFORE HRD 15-SEC BEFORE HRD 16-INMEDIATLY.
19-HOW MANY IS TIME DELAY FOR DISHARGE THE HRD ? (CARGO COMPARTMENT) IT BOTTLE DO NOT HAVE TIME DELAY 15-MIN 15 SEC.
20-How many bottles are discharged first on flight? (COMPARTMEN CARGO) TWO HIGHT RATE DISCHARGE. FIVE HIGHT RATE DISCHARGE. ONE HIGHT RATE DISCHARGE.
21 How many bottles will are discharged on ground? (COMPARTMEN CARGO) A-3 (TWO HRD /ONE LRD ONLY) B-2(ONE HRD /ONE LRD ONLY) C-5(ONE HRD/ FOUR LRD ONLY).
22- AIRPLANE ON GROUND. HOW MANY TIME DELAY FOR DISCHARGE THE LRD? A-NO, THERE IS NOT DELAY B-15-MIN C-15-SEC.
23-THE MAIN WHEEL WELL HAVE A-12 DETECTORS (6 LH WW AND 6 RH WW). B-6 DETECTORS (3 LH WW AND 3 RH WW). C-4 DETECTOR (2 LH WW AND 2 RH WW).
24- RED LED FLASHING SMOKE DETECTOR OF TOILET? MEAN A-SMOKE OR OVERTEMPERATURE B-FAIL C-IT REQUIERE MAINTENANCE ACTION, BUT SMOKE DETECTOR IS GOOD CONDITIONS.
24- RED LED FIXED ON SMOKE DETECTOR OF TOILET? MEAN A-IT REQUIERE MAINTENANCE ACTION, BUT SMOKE DETECTOR IS GOOD CONDITIONS. B-A-SMOKE OR OVER TEMPERATURE C-NOTHING.
26- THE ENGINE FIRE DETECTION SIGNAL GOES TO THE CDN THROUGH: MEDC EMU CAN (BUS).