axpu
|
|
Título del Test:
![]() axpu Descripción: test axpu |



| Comentarios |
|---|
NO HAY REGISTROS |
|
The APU oil cooler and electrical generator are cooled by: Bleed air pressure. A gear driven fan. An oil/fuel intercooler. An electric fan. Fuel for APU operation is normally obtained from. The APU tank in the aft fuselage. Right wing tank. Left wing tank. Centerline tank. APU fuel is heated automatically, if required. True. False. The APU oil is cooled by: A fuel/oil exchanger. A heat exchanger in the #1 (left) fuel tank. Positive airflow by a gear—driven fan. APU bleed air through temperature—controlled inlet guide vanes. The APU/OVERSPEED Light will illuminate when. a. APU RPM is excessive. b. During normal operation when APU overspeed protection has been lost. c. During APU shutdown when overspeed protection has been lost. d. Both a and C. The maximum altitude for use of the APU bleed air is ___ ft. 10,000. 17,000. 25,000. 35,000. The Battery Switch must be on during APU operation on the ground. True. False. The maximum altitude for using both an electrical load and the bleed air on the APU is ___ ft. 10,000. 17,000. 25,000. 35,000. The maximum altitude for APU operation is ___ ft. 10,000. 17,000. 35,000. 37,000. Momentarily positioning the APU switch to START will. Open the air inlet door. Open the Fuel Shutoff valve. After the air inlet door is open, cause the starter motor to engage. All of the above. Automatic shutdown will occur for. Overspeed or fire. Low oil pressure. High oil temperature. All of the above. The APU LOW OIL PRESSURE light will illuminate when. a. APU oil pressure is low. b. Starting APU. c. The APU switch is placed to the OFF position. d. Both a and b. The APU bleed air valve may be open after engine start as long as engine RPM does not go above idle. True. False. The Battery Switch should not be turned off until ____after the APU shuts down. 20 sec. 30 sec. NO DELAY. 1 min. The APU GEN OFF BUS Light will illuminate when the APU is at governed speed, ready to accept a load. True. False. The illumination of the APU DET INOP light indicates. APU fire detection is inoperative. That the APU should not be started. That the APU should be shut down if operating. All of the above. If positioning the APU Switch to the OFF position fails to shut down the APU, then. Pull the APU FIRE WARNING Switch. Turn off the Center Tank fuel boost pumps. Turn off the Left Tank fueL boost pumps. Manually close the APU FueL Shutoff Valve. Illumination of the APU FIRE WARNING Light will. a. Automatically discharge the APU fire bottle. b. Shutdown the APU. c. Unlock the APU FIRE WARNING Switch. d. Both b and c. Pulling and rotating the APU FIRE WARNING Switch will. Close the APU Fuel Shutoff VaLve. Discharge the APU fire bottle. Close the APU air inlet door. ALL of the above. Galley electrical Loads will be automatically shed should airplane power requirements exceed APU generator design limits. True. False. There is no requirement to monitor EGT during APU start. ¿¿¿¿¿¿¿¿. True. False. The illumination of the MAINT Light indicates that the APU should not be used for an extended period of operation. True. False. GARRETT -280 The maximum altitude for having an electrical load on the APU is. 10,000. 17,000. 37,000. 35,000. GARRETT -280 Which of the following will illuminate the APU OVERSPEED Light?. a. APU RPM is excessive. b. APU automatic start is aborted by the pilot. c. Overspeed shutdown protection is Lost during APU shutdown. d. a and c. Illumination of the APU FAULT Light. Will cause an automatic shutdown; the APU may not be restarted. Will cause an automatic shutdown; the APU may be restarted. Is only caused by high oil temperature. Will not cause an automatic shutdown. The maximum altitude for having an electrical load on the APU is. 10,000 ft. 17,000 ft. 35,000 ft. 37,000 ft. GARRETT —129 APU ONLY In the event of an APU EGT overtemp. a. The Bleed Air VaLve wiLl close rapidLy. b. The APU will continue to operate. c. The APU will automatically shut down. d. Both a and b. The maximum EGT for starting and transient conditions is. 700. 710. 750. 760. The maximum continuous EGT is. 700. 710. 750. 760. It is recommended that the APU be operated for ___ with no pneumatic Load prior to shut down. 30 sec. 15 sec. 1 min. 5 min. Illumination of the FAULT Light means that the oil is too hot for normal operation and the APU will shut down. True. False. |




