AC power frequency and voltage is. 240 CPS/115V. 400 CPS/115V. 60 CPS/110V. 400 CPS/240V.

The DC voltage of the battery and transformer/rectifier output is. 12V. 115V. 28V. 36V.

All generator bus sources must be manually connected through the movement of a switch. True. False.

When a new power source is switched onto a bus, the source that was previously powering the system is automatically disconnected. True. False.

On the ground, all the electrical busses may be supplied by. a. The APU generator. b. External AC ground power. c. One engine driven generator. d. Either a or b.

If one engine driven generator fails inflight, the _____ may be used to power all its busses. Other engine driven generator. APU generator. Battery. Battery charger.

Each transfer bus has an associated transfer relay which automatically selects the opposite generator bus as a power supply if its normal source fails and the transfer switch is in AUTO. True. False.

Under normal inf light operating conditions, what is the relationship of the No. 1 electrical system to the No. 2 electrical system?. Completely independent AC and DC busses. Independent AC busses, paralleled DC busses. Paralleled AC busses, independent DC busses. Parallel AC and DC busses.

Each transfer bus has an associated transfer relay which automatically selects the opposite generator bus as an alternate power supply if its primary source fails. (BUS TRANSFER — AUTO). True. False.

In flight, the Standby AC and DC busses can be powered from. a. Battery Bus. b. Transfer Bus No. 1. c. Transfer Bus No. 2. d. Either a or b.

DC power required for systems control, Light, communications and navigation equipment can be supplied by. a. Transformer/Rectifier (T/R) units. b. Battery. c. No. 1 Main Bus. d. Both a and b.

The AC Standby Bus is normally powered by. Transfer Bus No. 1. Main Bus No. 1. Main Bus No. 2. Transfer Bus No. 2.

The DC Standby Bus is normally powered by. Battery Bus. No. 1 DC Bus. No. 2 DC Bus. T/R No. 3.

Transformer/Rectifier No. 3 receives its power from. No. 1 Generator Bus. No. 1 Main Bus. No. 2 Transfer Bus. No. 2 Main Bus.

Normal operation of a T/R may be confirmed by positioning the DC METER switch to the desired T/R position and observing a positive reading on the DC AMPS meter. True. False.

The T/R No. 3 disconnect relay automatically opens at glide slope capture. To prevent a single bus failure from affecting both navigation receivers and flight control computers. To provide more power to the AC Standby bus. To ensure that the Standby DC bus is powered. All of the above.

The maximum Generator Drive oil temperature is. 20°C. 157°C. 150°C. 145°C.

Illumination of the Generator Drive LOW OIL PRESSURE Light requires the crew to. Trip the respective generator circuit breaker. Check the drive temperature for both IN and RISE. Land as soon as possible. Disconnect the Generator Drive.

When you disconnect the Generator Drive for Generator No. 1 in flight, what three lights of the electrical system illuminate? (APU not running). Generator Drive LOW OIL PRESSURE, GEN OFF BUS, BUS OFF. Generator Drive LOW OIL PRESSURE, APU GEN OFF BUS, STANDBY POWER OFF. TRANSFER BUS OFF, BUS OFF, GEN OFF BUS. STANDBY PWR OFF, HIGH OIL TEMP, GEN OFF BUS.

On the ground, the STANDBY PWR OFF Light wilL normally extinguish when. a. The Battery Switch is positioned to ON. b. STANDBY POWER is positioned to BAT. c. Any AC source is connected to the generator buses. d. Either b or c.

An inf light loss of all generators requires the crew to immediately position the STANDBY POWER Switch to the BAT position. True. False.

The maximum generator drive oil temperature rise is. 20°C. 30°C. 160°C. 25°C.

The Battery Switch must be ON in order to connect ground power to the aircraft systems. True. False.

InfIight, electrical load shedding automatically turns off the galley power when operating on one generator. This reduces power demand and ensures that the remaining generator will not be overloaded. True. False.