FAA Ignition and Starting Systems (Recip) 2
|
|
Título del Test:
![]() FAA Ignition and Starting Systems (Recip) 2 Descripción: some questions |



| Comentarios |
|---|
NO HAY REGISTROS |
|
The spark is produced in a magneto ignition system when the breaker points are. fully open. beginning to open. fully closed. The secondary coil of a magneto is grounded through the. ignition switch. primary coil. ground side of the breaker points. Upon inspection of the spark plugs in an aircraft engine, the plugs were found caked with a heavy black soot. This indicates. worn oil seal rings. a rich mixture. a lean mixture. What components make up the magnetic system of a magneto?. Pole shoes, the pole shoe extensions, and the primary coll. Primary and secondary coils. Rotating magnet, the pole shoes, the pole shoe extensions, and the coil core. The type of ignition system used on most turbine aircraft engines is. high resistance. low tension. capacitor discharge. Why are high-tension ignition cables frequently routed from the distributors to the spark plugs in flexible metallic conduits?. To eliminate high altitude flashover. To reduce the formation of corona and nitric oxide on the cable insulation. To reduce the effect of the high-frequency electromagnetic waves emanated during operation. Alignment of the marks provided for internal timing of a magneto indicates that the. breaker points are just beginning to close for cylinder 1. magneto is in E-gap position. compression stroke. The E-gap angle is usually defined as the number of degrees between the neutral position of the rotating magnet and the position. where the contact points close. where the contact points open. of greatest magnetic flux density. If an aircraft ignition switch is turned off and the engine continues to run normally, the trouble is probably caused by. an open ground lead in the magneto. arcing magneto breaker points. primary lead grounding. When the ignition switch of a single (reciprocating) engine aircraft is turned to the OFF position,. the primary circuits of both magnetos are grounded. the secondary circuits of both magnetos are opened. all circuits are automatically opened. When using an electric starter motor, the current flow through it. is highest just before starter cutoff (at highest RPM). remains relatively constant throughout the starting cycle. is highest at the start of motor rotation. Which of the following breaker point characteristics is associated with a faulty capacitor?. Crowned. Fine grained. Coarse grained. What will be the result of using too hot a spark plug?. Fouling of plug. Preignition. Burned capacitor. Shielding is used on spark plug and ignition wires to. Protect the wires from short circuits as a result of chafing or rubbing. Prevent outside electromagnetic emissions from disrupting the operation of the ignition system. Prevent interference with radio reception. A spark plug is fouled when. its spark grounds by jumping electrodes. it causes preignition. its spark grounds without jumping electrodes. The numbers appearing on the ignition distributor block indicate the. sparking order of the distributor. relation between distributor terminal numbers and cylinder numbers. firing order of the engine. When internally timing a magneto, the breaker points begin to open when. the piston has just passed TDC at the end of the compression stroke. the magnet poles are a few degrees beyond the neutral position. the magnet poles are fully aligned with the pole shoes. Thermocouples are usually inserted or installed on the. front cylinder of the engine. rear cylinder of the engine. hottest cylinder of the engine. Which of the following statements is true?. The platinum and iridium ground electrodes used on fine wire spark plugs are extremely brittle and can be broken if they are improperly handled or adjusted. When gapping massive-electrode spark plugs, a wire gauge should be inserted between the center and ground electrodes while moving the ground electrode to avoid setting the gap too close. The platinum and iridium ground electrodes used on fine wire spark plugs are extremely strong and not easily broken when handled or adjusted. Defective spark plugs will cause the engine to run rough. during run up. during cruise. at all speeds. What is the radial location of the two north poles of a four-pole rotating magnet in a high-tension magneto?. 180° apart. 270° apart. 90° apart. Which of the following are distinct circuits of a high tension magneto?. Magnetic, primary, and secondary. Magnetic, E-gap, and P lead. Primary, P lead, and secondary. Which of the following would be cause for rejection of a spark plug?. Carbon fouling of the electrode and insulator. Insulator tip cracked. Lead fouling of the electrode and insulator. Spark plug heat range is determined by. the reach of the spark plug. its ability to transfer heat to the cylinder head. the number of ground electrodes. What is the difference between a low-tension and a high-tension engine ignition system?. A low-tension system produces relatively low voltage at the spark plug as compared to a high-tension system. A high-tension system is designed for high-altitude aircraft, while a low-tension system is for low- to medium-altitude aircraft. A low-tension system uses a transformer coil near the spark plugs to boost voltage, while the high-tension system voltage is constant from the magneto to the spark plugs. Magneto breaker point opening relative to the position of the rotating magnet and distributor rotor (internal timing) can be set most accurately. during the magneto-to-engine timing operation. during assembly of the magneto before installation on the engine. by setting the points roughly at the required clearance before installing the magneto and then making the fine breaker point adjustment after installation to compensate for wear in the magneto drive train. In an aircraft ignition system, one of the functions of the capacitor is to. regulate the flow of current between the primary and secondary coll. facilitate a more rapid collapse of the magnetic field in the primary coil. stop the flow of magnetic lines of force when the points open. |





