option
Cuestiones
ayuda
daypo
buscar.php

NCP-MCI-6.10 Nutanix 22 a 34

COMENTARIOS ESTADÍSTICAS RÉCORDS
REALIZAR TEST
Título del Test:
NCP-MCI-6.10 Nutanix 22 a 34

Descripción:
Apenas para estudo pessoal

Fecha de Creación: 2026/01/22

Categoría: Otros

Número Preguntas: 13

Valoración:(0)
COMPARTE EL TEST
Nuevo ComentarioNuevo Comentario
Comentarios
NO HAY REGISTROS
Temario:

An administrator is trying to configure Metro Availability between Nutanix ESXi-based clusters. However, the Compatible Remote Sites screen does not list all required storage containers. ---- Which two reasons could be a cause for this issue? (Choose two.). Source and destination hardware are from different vendors. The remote site storage container has compression enabled. The destination storage container is not empty. Both storage containers must have the same name.

An administrator is trying to configure Metro Availability between Nutanix ESXi-based clusters. However, the Compatible Remote Sites screen does not list all required storage containers. ---- Which two reasons could be a cause for this issue? (Choose two.). Source and destination hardware are from different vendors. The remote site storage container has compression enabled. The destination storage container is not empty. Both storage containers must have the same name.

Refer to Exhibit: ---- An administrator is looking at the memory cluster runway diagram as shown in exhibit, in Prism Central. The environment has three hosts with the following configuration: CPU: 2x Intel Xeon Gold (8 cores, 2.6 GHz) RAM: 256 GB per host Storage: SSDs and HDDs The Intelligent Operations feature has been active for one month, but no further configurations were applied. What does the dotted red line mean?. It is the default trend analysis static threshold that can be manually set. It is the maximum memory the administrator can assign to VMs. It is the calculated memory oversubscription limit for currently running VMs. It is the usable capacity based on cluster configuration options.

An administrator receives complaints about VM performance. After reviewing the VMs CPU Ready Time data, which step should the administrator take to diagnose the issue further?. Check the number of vCPUs assigned to each CVM. Review host CPU utilization. Assess cluster SSD capacity. Enable VM memory oversubscription.

Due to application requirements, an administrator needs to support a multicast configuration in an AHV cluster. Which AHV feature can be used to optimize network traffic so that multicast traffic is only forwarded to the VMs that need to receive it?. LACP. UDP. IGMP Snooping. Network Segmentation.

An administrator migrated a physical MySQL database from a legacy 3-tier environment to a Nutanix cluster. After migration, the administrator finds that at peak load, the number of IOPS is lower than expected, and latency is higher. Which two steps should the administrator take to improve performance? (Choose two.). Ensure that the SQL data vDisks are thick provisioned. Create additional vDisks for SQL data. Use LVM to stripe the SQL data across multiple vDisks. Ensure that the SQL data vDisks are thin provisioned.

An administrator migrated a physical MySQL database from a legacy 3-tier environment to a Nutanix cluster. After migration, the administrator finds that at peak load, the number of IOPS is lower than expected, and latency is higher. Which two steps should the administrator take to improve performance? (Choose two.). Ensure that the SQL data vDisks are thick provisioned. Create additional vDisks for SQL data. Use LVM to stripe the SQL data across multiple vDisks. Ensure that the SQL data vDisks are thin provisioned.

After upgrading Prism Central from PC2022.1 to PC2024.1, an administrator is unable to log in with their IAM domain account. What is the first troubleshooting step the administrator should take?. Ping the Domain Controller from the CVM. Ensure port 9441 is open in the firewall. Validate the trusted signing certificate of the organization. Log in with a local admin account.

An administrator has successfully configured Metro Availability for a Protection Domain. However, after a few days, an NCC warning is raised: "Following VMs are accessing data from remote clusters: VM-1 from remote cluster Remote-ML" What is the first action an administrator must take to fix the issue?. Run the command: ncli pd list metro-avail=true | egrep "Protection Domain Stretch Role" | grep "ACTIVE". Use must-affinity rules to avoid automated VM migration to the standby datastore. Migrate the VM to its primary site and set appropriate rules for DRS and affinity. Run the command: ncc health_checks metro_availability_checks data_locality_check --cvm_list=X.X.X.20.

An administrator is trying to delete a protected snapshot but is unable to do so. What is the most likely cause?. There is an active recovery occurring at that time. Ransomware has encrypted the snapshot. There is an approval policy that was denied. The snapshot has been corrupted.

When expanding a cluster, what is required to automatically discover new nodes?. New nodes must have the same hypervisor version. IPv6 multicast must be allowed on physical switches. New nodes must have the same AOS version. IPv4 multicast must be allowed on physical switches.

In a scale-out Prism Central deployment, what additional functionality does configuring an FQDN instead of a Virtual IP provide?. Load balancing. Resiliency. Segmentation. SSL Certificate.

An administrator wants to disable password-based SSH access for the nutanix user on a CVM to improve security. What action should the administrator take?. Rename the nutanix user. Block port 22 on the CVM firewall. Enable Cluster Lockdown. Delete the nutanix user.

Denunciar Test