The pressure switch generates LOW AIR PRESS warning if the pressure on the reservoir is. less than 22 psi. more than 22 psi. less than 22 bar.

the bypass operates when the differential pressure across the filter is. more than 29 ± 2.35 bar (2 ± 0.16 psi). less than 29 ± 2.35 psi (2 ± 0.16 bar). more than 29 ± 2.35 psi (2 ± 0.16 bar).

The system relief valve connects the HP circuit to the return circuit in case of overpressure. The relief valve close at: 3436 psi (237 bar) and open at 3190 psi (220 bar). The relief valve opens at: 3436 psi (237 bar) and closes at 3190 psi (220 bar). The relief valve opens at: 3436 bar (237 psi) and closes at 3190 bar (220 psi).

The threshold of the pressure switches on the hp maniforld on the yellow hydrualic system. 1450 bar (99.5 psi). 1450 psi (99.5 bar). 1400 psi (99.5 bar).

The High Pressure (HP) filter has a clogging indicator. The clogging indicator operates when: when the differential pressure is. higher than 87 ± 8.7 psi (6 ± 0.6 bar). less than 87 ± 8.7 psi (6 ± 0.6 bar). higher than 87 ± 8.7 bar (6 ± 0.6 psi).

The PTU is inhibited on ground if. The cargo door operation. And during the first engine, if parking brake is set on or nose wheel steering is connected for towing. The cargo door operation. And during the first engine, if parking brake is set off or nose wheel steering is disconnected for towing. The cargo door operation. And during the first engine, if parking brake is set on or nose wheel steering is disconnected for towing.

the Power Transfer Unit (PTU) will run automatically when. The differential pressure between the green and yellow circuits is: less than 500 psi (34.5 bar). The differential pressure between the green and yellow circuits is: greater than 500 psi (34.5 bar). The differential pressure between the green and blue circuits is: greater than 500 psi (34.5 bar).

In case of cargo door operation, the PTU is inhibited if. the yellow leak measurement valve is closed and a signal is sent to the Slat Flap Control Computer (SFCC) 2 to prevent flaps movement. the yellow leak measurement valve is opened and a signal is sent to the Slat Flap Control Computer (SFCC) 2 to prevent flaps movement. the yellow leak measurement valve is closed and a signal is sent to the Slat Flap Control Computer (SFCC) 1 to prevent flaps movement.

The yellow electric pump runs if. the HYD PUMP P/B is set to ON,. the ELEC PUMP P/B is set to OFF. the ELEC PUMP P/B is set to ON,.

The hand pump is installed on the ground service panel of the yellow system: Is used for electrical cargo door operation only. Is used for manual cargo door operation only. Is used for manual pressuration only.

The threshold of the pressure switch on the yellow hydraulic EDP. is 1740 psi (120 bar). is 1740 bar (120 psi). is 1700 psi (120 bar).

wich are the threshold of the LP switch of the yellow hydraulic reservor. 22 bar (1.52psi). 22 psi (1.52bar). 20 psi (1.52bar).

Which sentence is correct?. There are no hydraulic pipes in the passenger cabin or flight compartment. There are hydraulic pipes in the passenger cabin or flight compartment. There are no hydraulic pipes in cargo compartment or flight compartment.

where is RAT retraction module controls by the RAT stowage procedure. is located on the blue servicing panel. is located on the yellow servicing panel. is located on the green servicing panel.

The PTU operation is inhibited when. at first engine start and during cargo door operation. during cargo door operation. at first engine start.

what is a leakage. leakage is a quantity of fluid on the surface of a component that is not sufficient to become a drop. leakage is a quantity of fluid on the surface of a component that is sufficient to become a drop. leak is a quantity of fluid on the surface of a component that is not sufficient to become a drop.

what is a leak. A leak is the quantity of fluid that comes out of a component and that is sufficient to become a drop or drops, or will possibly become a drop. A leak is the quantity of fluid that comes out of a component and that no is sufficient to become a drop or drops, or will possibly become a drop. A leakage is the quantity of fluid that comes out of a component and that is sufficient to become a drop or drops, or will possibly become a drop.

the reservoir pressurization can be done via. a pneumatic ground cart connected to the reservoir pressure unit, or the pneumatic system ground connection. a Hydraulic ground cart connected to the reservoir pressure unit, the APU, or the pneumatic system ground connection. a pneumatic ground cart connected to the reservoir pressure unit, the APU, or the pneumatic system ground connection.

there are two water drains. one is automatic after engines and APU shut down, and the other is manually operated. one is automatic after engines and APU shut down, and the other is electrical operated. two are automatic after engines and APU shut down.

all tree reservoirs are pressurized from Engine 1 for normal supply and the bleed air system for alternate supply at. 43 bar. 40 psi. 43 psi.